B116, C15 Jalan Haji Ahmad, Perkampungan Seri Setali, 25300 Kuantan, Pahang, Malaysia.

+6019-323 7617

kstoolsdepot@gmail.com


Share:


LEO INVERTER HORIZONTAL MULTISTAGE PUMPS - BP-ECH 20-10



Product Description

The LEO BP-ECH 20-10 is an intelligent inverter-controlled horizontal multistage centrifugal pump designed for automatic water pressure boosting and constant-pressure water supply applications. It combines a horizontal multistage pump with an integrated variable-frequency drive (VFD), allowing the pump speed to automatically adjust according to water demand.

The inverter system helps maintain stable outlet pressure while reducing unnecessary power consumption. When water demand increases, the pump increases its operating speed; when demand decreases, the speed is reduced accordingly. The system can also stop automatically when there is no water demand.

The BP-ECH 20-10 is suitable for residential, commercial and light industrial water supply systems where reliable pressure control, quiet operation and energy efficiency are required.

Key Features

• Intelligent inverter-controlled operation
• Horizontal multistage centrifugal pump design
• Automatic constant-pressure water supply
• Variable-speed operation according to water demand
• Energy-saving operation compared with conventional fixed-speed pumps
• Automatic start and stop function
• Integrated electronic control system
• Multiple-stage impeller arrangement for higher pressure generation
• Compact horizontal configuration
• Stainless-steel wetted pump components for improved corrosion resistance
• Low-noise operation
• Suitable for frequent start/stop applications
• Built-in protection functions for safer pump operation
• Automatic pressure adjustment
• Easy operation and reduced manual control requirements
• Suitable for single-pump domestic and commercial boosting applications

Product Specifications

Specification BP-ECH 20-10
Brand LEO
Series BP-ECH
Model BP-ECH 20-10
Pump Type Inverter Horizontal Multistage Pump
Pump Construction Horizontal Multistage Centrifugal
Control Type Intelligent Variable-Frequency / Inverter Control
Application Automatic Water Pressure Boosting
Pump Orientation Horizontal
Operating Mode Automatic Variable Speed
Pressure Control Constant Pressure
Starting/Stopping Automatic
Motor Type High-Efficiency Electric Motor
Impeller Arrangement Multistage
Installation Horizontal
Suitable Fluid Clean Water
Control Integrated Electronic Controller
Typical Use Residential, Commercial & Light Industrial Water Supply

Operating Principle

The BP-ECH 20-10 uses an integrated pressure-control and inverter system to regulate pump speed according to actual water consumption.

  1. When a tap or outlet is opened, system pressure decreases.
  2. The pressure sensor detects the pressure change.
  3. The inverter controller increases motor speed to compensate for the pressure drop.
  4. The pump delivers the required flow while maintaining stable pressure.
  5. When water demand decreases, the inverter reduces the motor speed.
  6. When all outlets are closed and demand reaches zero, the pump automatically stops.

This variable-speed operation avoids running the motor continuously at maximum speed when full pump capacity is not required.

Applications

The LEO BP-ECH 20-10 can be used for:

• Domestic water pressure boosting
• High-rise residential water supply
• Landed houses and multi-storey homes
• Apartments and condominiums
• Hotels and guest houses
• Offices and commercial buildings
• Restaurants and food-service premises
• Shops and retail premises
• Small factories and workshops
• Water transfer and distribution systems
• General clean-water pressure boosting
• Rainwater harvesting systems
• Water tank pressure boosting
• Irrigation and gardening systems
• Automatic water supply systems

Advantages of Inverter Control

Compared with a conventional fixed-speed booster pump, the inverter-controlled BP-ECH system can provide more precise pressure regulation. The motor does not need to operate continuously at maximum speed. Instead, the controller adjusts the operating speed to match actual water consumption.

This can provide:

• More stable water pressure
• Lower energy consumption during partial-load operation
• Reduced pressure fluctuations
• Softer pump starting and stopping
• Reduced mechanical stress
• Better user comfort
• Automatic operation
• Improved system efficiency

Multistage Pump Design

The horizontal multistage construction uses multiple impeller stages arranged within the pump assembly. Each stage contributes to the total pressure developed by the pump. This configuration allows the pump to provide higher discharge pressure while maintaining a relatively compact horizontal design.

The multistage arrangement makes the BP-ECH series suitable for applications where higher pressure is required than a conventional single-stage centrifugal pump can provide.

Recommended Installation

For reliable operation, the pump should be installed on a firm, level surface with adequate clearance for inspection and maintenance.

The installation should include:

• Correctly sized suction and discharge piping
• Proper pipe supports
• Appropriate isolation valves
• Suitable non-return/check valve where required
• Clean water supply
• Adequate water source capacity
• Correct electrical supply
• Proper grounding/earthing
• Protection against dry-running conditions
• Adequate ventilation around the motor/controller

The suction pipe should be installed to minimize air entry and excessive friction losses. Where the pump draws water from a storage tank, the suction arrangement should be designed to maintain adequate water supply to the pump.

Suitable Water

The BP-ECH 20-10 is intended primarily for clean water and similar liquids that are not chemically aggressive and do not contain excessive abrasive particles.

Typical suitable applications include:

• Fresh water
• Tank water
• Treated water
• Clean rainwater
• General service water

Avoid pumping liquids containing significant quantities of sand, mud, abrasive solids, corrosive chemicals or other substances outside the manufacturer's specified operating range.

Maintenance

Routine maintenance should include:

• Inspecting pipe connections for leakage
• Checking pump operation and pressure stability
• Keeping the pump and inverter controller clean
• Checking electrical connections
• Inspecting valves and piping
• Ensuring adequate water supply
• Checking for abnormal vibration or noise
• Preventing prolonged dry running
• Inspecting the system periodically for wear or leakage



 Inquiry - LEO INVERTER HORIZONTAL MULTISTAGE PUMPS - BP-ECH 20-10