B116, C15 Jalan Haji Ahmad, Perkampungan Seri Setali, 25300 Kuantan, Pahang, Malaysia.

+6019-323 7617

kstoolsdepot@gmail.com


Share:


LEO MULTISTAGE CENTRIFUGAL PUMPS - 4ACM 60



The LEO 4ACm60 is a compact four-stage horizontal multistage centrifugal pump designed for clean-water transfer, domestic water supply, pressure boosting, garden irrigation, long-distance water transfer and light industrial applications. It uses a 0.6 kW / approximately 0.8 HP, 220–240V single-phase motor, four thermoplastic impeller stages, an AISI 304 stainless-steel shaft, and 1" × 1" suction/discharge connections. LEO identifies the ACm range for clean-water transfer, urban water supply, pressure boosting, irrigation, HVAC circulation and related applications.

Product Specifications

Specification 4ACm60
Brand LEO
Model 4ACm60 / 4ACM60
Pump Type Horizontal Multistage Centrifugal Pump
Number of Stages 4
Motor Power 0.60 kW
Motor Rating Approx. 0.8 HP
Motor Type Single Phase
Voltage 220–240V
Frequency 50 Hz
Maximum Flow Approx. 70 L/min
Maximum Flow Approx. 4.2 m³/h
Maximum Head Approx. 45 m
Head Range Approx. 45–10 m
Maximum Suction Height 8 m
Suction Connection 1"
Discharge Connection 1"
Inlet / Outlet 1" × 1"
Impeller Thermoplastic
Pump Body Cast Iron
Pump Support Cast Iron
Shaft AISI 304 Stainless Steel
Mechanical Seal Carbon / Ceramic
O-Ring NBR
Motor Winding Copper
Insulation Class F
Protection Class IPX4
Motor Protection Built-in Thermal Protection
Construction Horizontal
Pump Function Self-Priming
Maximum Liquid Temperature 40°C*
Maximum Ambient Temperature 40°C*

LEO's 2026 European brochure groups the 4ACm75 with the 3ACm60 as the ACm cast-iron multistage range, while Malaysian product listings specifically identify the 4ACm60 as a four-stage, 0.6 kW, 220V model with approximately 5–70 L/min flow and 45–10 m head.

Hydraulic Performance

The 4ACm60 is designed primarily for higher-pressure, moderate-flow applications.

The published specification gives approximately:

Parameter 4ACm60
Minimum listed flow Approx. 5 L/min
Maximum flow Approx. 70 L/min
Maximum flow Approx. 4.2 m³/h
Maximum head Approx. 45 m
High-flow head Approx. 10 m
Suction height Up to 8 m
Connection 1" × 1"

The important point is that 45 m maximum head and 70 L/min maximum flow are different operating points. The actual duty point depends on the system curve, elevation, pipe friction, fittings and required discharge pressure.

Four-Stage Multistage Design

The "4" in the 4ACm60 designation refers to the pump's four hydraulic stages/impellers.

Each stage contributes additional pressure, with the stages operating in series. This allows the pump to produce significantly higher head than a comparable single-stage centrifugal pump.

The four-stage configuration is particularly useful for:

  • Pressure boosting
  • Long pipe runs
  • Elevated water transfer
  • Domestic water supply
  • Irrigation systems
  • Small high-pressure applications
  • Water circulation

The ACm family is specifically designed as a cast-iron multistage pump range, with thermoplastic impellers and AISI 304 stainless-steel shaft construction.

0.6 kW Motor

The 4ACm60 uses a 0.6 kW single-phase motor, making it suitable for installations where a standard 220–240V electrical supply is available.

Key motor characteristics include:

  • Power: 0.60 kW
  • Approximate rating: 0.8 HP
  • Voltage: 220–240V
  • Single phase
  • 50 Hz
  • Copper winding
  • Class F insulation
  • IPX4 protection
  • Built-in thermal protection

LEO specifies integrated thermal protection for single-phase motors, Class F insulation and IPX4 protection for this pump family.

Self-Priming Capability

The ACm range is specified as self-priming, with a maximum suction height of approximately 8 m.

This allows the 4ACm60 to be installed above a water source in suitable suction-lift applications.

Typical installations include:

  • Storage tanks
  • Ground-level reservoirs
  • Rainwater tanks
  • Wells
  • Garden water sources
  • Irrigation tanks

Proper initial priming is still required. Self-priming capability does not mean the pump is suitable for dry running.

1" × 1" Connections

The pump has:

Suction: 1"
Discharge: 1"

The 1" connections make the pump suitable for common domestic, irrigation and small industrial pipework.

For optimum hydraulic performance:

  • Keep the suction pipe short.
  • Use an appropriate suction-pipe diameter.
  • Minimize sharp bends.
  • Avoid unnecessary reducers.
  • Ensure suction joints are airtight.
  • Use a suitable foot valve/strainer where required.

Pump Construction

The 4ACm60 uses a cast-iron pump body and support with special anti-rust treatment. The shaft is manufactured from AISI 304 stainless steel.

The multistage hydraulic assembly uses thermoplastic components. This construction helps keep the pump compact while providing the multiple stages required to generate higher pressure.

Main construction materials include:

  • Cast-iron pump body
  • Cast-iron support
  • Thermoplastic impellers
  • Thermoplastic diffusers
  • AISI 304 stainless-steel shaft
  • Carbon/ceramic mechanical seal
  • NBR sealing elements

AISI 304 Stainless-Steel Shaft

The AISI 304 stainless-steel shaft provides corrosion resistance and mechanical strength for the four-stage hydraulic assembly.

This is particularly important because the shaft simultaneously drives the multiple impeller stages.

Mechanical Seal

The pump uses a carbon/ceramic mechanical seal to prevent water from escaping along the rotating shaft into the motor section.

Proper priming and adequate water supply are important for mechanical-seal life. Dry running should be avoided.

Suitable Fluids

The 4ACm60 is intended for clean water or liquids with physical and chemical characteristics comparable to water.

Suitable applications include:

  • Clean fresh water
  • Treated water
  • Tank water
  • Clean well water
  • Irrigation water
  • Domestic water
  • General service water

It is not intended for abrasive slurry, heavily contaminated wastewater or chemically aggressive liquids unless material compatibility is confirmed.

Applications

The LEO 4ACm60 is suitable for:

  • Domestic water supply
  • Residential pressure boosting
  • Garden irrigation
  • Agricultural irrigation
  • Small sprinkler systems
  • Water transfer
  • Storage-tank transfer
  • Long-distance water transfer
  • Industrial water supply
  • HVAC water circulation
  • Hot/cold water circulation
  • Pressure boosting
  • Supporting equipment

LEO's official ACm documentation lists industrial use, urban water supply, pressure boosting, fire-fighting systems, garden irrigation, long-distance water transfer, air-conditioning systems and circulation/pressure boosting among the applications.

Domestic Water Supply

The four-stage design makes the 4ACm60 particularly useful when a domestic system requires more pressure than a basic single-stage pump can provide.

Typical applications include:

  • House water supply
  • Water tank transfer
  • Shower pressure boosting
  • Garden tap supply
  • Small residential booster systems
  • Water distribution
  • Elevated water transfer

The actual flow should be selected according to the required pressure and total dynamic head.

Garden & Agricultural Irrigation

The 4ACm60 is suitable for small-to-medium irrigation systems where the operating point falls within its hydraulic curve.

Potential uses include:

  • Lawn irrigation
  • Garden sprinklers
  • Nursery irrigation
  • Greenhouse irrigation
  • Small farm irrigation
  • Orchard irrigation
  • Tank-to-field transfer

The maximum listed flow is approximately 70 L/min or 4.2 m³/h, but the available flow decreases as required head increases.

Pressure Boosting

The four-stage hydraulic arrangement is one of the primary advantages of the 4ACm60.

It is suitable for pressure boosting where the system needs additional head for:

  • Multiple outlets
  • Elevated buildings
  • Long pipe runs
  • Irrigation sprinklers
  • Storage-tank systems
  • Domestic water distribution

The pump should be selected according to the actual duty point rather than the maximum-head figure alone.

Long-Distance Water Transfer

The 4ACm60 can be used to transfer clean water through relatively long pipe runs where friction losses would otherwise reduce the available pressure.

The multistage design provides additional head to overcome:

  • Pipe friction
  • Elevation
  • Valves
  • Filters
  • Fittings
  • Other system resistance

Correct pipe sizing remains important because excessive friction can substantially reduce flow.

Fire-Fighting Applications

LEO lists fire-fighting/overpressure applications within the ACm family.

However, the 4ACm60 should not automatically be marketed as a certified fire pump. For a regulated fire-protection system, the complete installation must meet the applicable standard and certification requirements.

Maximum Suction Height

The maximum suction height specified for the ACm family is approximately 8 m.

Actual suction performance depends on:

  • Atmospheric pressure
  • Installation elevation
  • Water temperature
  • Suction-pipe diameter
  • Suction-pipe length
  • Pipe fittings
  • Water level
  • Air leakage
  • Friction losses

For suction-lift applications, the suction line should be short, direct and completely airtight.

Operating Temperature

LEO's European specification gives:

Maximum liquid temperature: +40°C
Maximum ambient temperature: +40°C.

Some regional Malaysian listings for the 4ACm60 state a higher water-temperature figure of 60°C. Because these values differ by source/version, the safest website specification is to state 40°C unless the nameplate or manufacturer documentation supplied with your exact stock confirms 60°C.

Motor Protection

The 4ACm60 motor provides:

Insulation: Class F
Protection: IPX4
Thermal protection: Integrated for single-phase motor.

IPX4 protects the motor against water splashing from different directions, but the motor should not be submerged or exposed to high-pressure water jets.

Installation Recommendations

For reliable operation:

  • Install the pump on a firm, level base.
  • Position it as close as practical to the water source.
  • Keep suction piping short and direct.
  • Use suitable 1" suction piping.
  • Ensure all suction connections are airtight.
  • Install a foot valve/strainer where required.
  • Support connected pipework independently.
  • Avoid excessive elbows and restrictions.
  • Prime the pump before initial operation.
  • Confirm correct motor rotation where applicable.
  • Provide proper electrical earthing.
  • Use suitable electrical protection.
  • Do not operate the pump dry.
  • Prevent debris from entering the hydraulic assembly.
  • Operate within the manufacturer's hydraulic curve.

Maintenance

Recommended maintenance includes:

  • Checking for water leakage
  • Inspecting the mechanical seal
  • Checking suction-line air leakage
  • Cleaning the suction strainer
  • Inspecting impellers and diffusers
  • Checking for abnormal vibration
  • Checking for unusual operating noise
  • Monitoring motor temperature
  • Checking electrical connections
  • Monitoring pressure and flow
  • Inspecting valves and pipework

Regular inspection is particularly important when the pump operates continuously.

4ACm60 vs 3ACm45

Specification 3ACm45 4ACm60
Number of Stages 3 4
Motor Power 0.45 kW 0.60 kW
Motor Rating 0.6 HP Approx. 0.8 HP
Supply 220–240V 220–240V
Maximum Head Approx. 38 m Approx. 45 m
Maximum Flow Approx. 70 L/min Approx. 70 L/min
Maximum Flow Approx. 4.2 m³/h Approx. 4.2 m³/h
Connection 1" × 1" 1" × 1"
Maximum Suction 8 m 8 m
Main Advantage Lower power consumption Higher pressure/head

The 4ACm60 adds one hydraulic stage and increases motor power from 0.45 kW to 0.60 kW, giving it greater maximum head capability. LEO's published range information supports the higher-head positioning of the four-stage model.

4ACm60 vs 4ACm75

Specification 4ACm60 4ACm75
Number of Stages 4 4
Motor Power 0.60 kW 0.75 kW
Motor Type Single Phase Single Phase
Maximum Flow Approx. 4.2 m³/h Approx. 5.4 m³/h
Maximum Head Approx. 45 m Approx. 46.5 m
Connection 1" × 1" 1" × 1"
Main Advantage Compact/lower power Higher capacity

LEO's 2026 brochure lists the ACm multistage cast-iron range with 3ACm60 and 4ACm75, maximum volumes of approximately 4.2 and 5.4 m³/h and maximum heads of approximately 35 and 46.5 m, respectively.

Key Advantages

Four-Stage Design: Produces higher pressure from a compact horizontal pump.

0.6 kW Motor: Provides a useful balance between power consumption and hydraulic performance.

Up to Approx. 45 m Head: Suitable for domestic pressure boosting, irrigation and elevated water transfer.

Up to Approx. 70 L/min Flow: Suitable for small-to-medium water-transfer applications.

AISI 304 Stainless-Steel Shaft: Provides corrosion resistance and durability.

Thermoplastic Hydraulic Stages: Keep the multistage assembly compact.

Self-Priming: Suitable for appropriate suction-lift installations.

1" × 1" Connections: Convenient for domestic and irrigation pipework.

220–240V Single Phase: Suitable for standard single-phase electrical supplies.

IPX4 / Class F Motor: Provides practical protection for general pumping installations.

Product Summary

The LEO 4ACm60 is a 0.60 kW / approximately 0.8 HP, 220–240V single-phase, four-stage horizontal multistage centrifugal pump designed for clean-water transfer and pressure applications. It features a 1" × 1" inlet/outlet, cast-iron pump body and support, thermoplastic hydraulic stages, an AISI 304 stainless-steel shaft, carbon/ceramic mechanical seal and built-in motor thermal protection.

The model is commonly specified for approximately 5–70 L/min flow, 45–10 m head, and 8 m maximum suction height. This makes it suitable for domestic water supply, pressure boosting, garden and agricultural irrigation, long-distance water transfer, HVAC circulation and light industrial water applications.