B116, C15 Jalan Haji Ahmad, Perkampungan Seri Setali, 25300 Kuantan, Pahang, Malaysia.

+6019-323 7617

kstoolsdepot@gmail.com


Share:


LEO END SUCTION CENTRIFUGAL PUMPS - LEZ 125-100-160/176-2



The LEO LEZ 125-100-160/176-2 is a heavy-duty end-suction centrifugal water pump designed for high-volume water transfer and industrial, commercial, irrigation, building-services and general water-supply applications. The model is listed within LEO's industrial centrifugal-pump range in Malaysia.

The LEZ series is intended for applications where a conventional domestic centrifugal pump is insufficient and a more robust, higher-capacity pump configuration is required. Its end-suction arrangement provides a practical layout for installation in water-supply, circulation and transfer systems.

Product Specifications

Specification LEO LEZ 125-100-160/176-2
Brand LEO
Model LEZ 125-100-160/176-2
Pump Type End-Suction Centrifugal Pump
Series LEZ
Pump Configuration Horizontal End-Suction
Impeller Type Closed Centrifugal Impeller
Suction Connection DN125
Discharge Connection DN100
Nominal Impeller Diameter 160 mm
Maximum Impeller Diameter 176 mm
Drive Configuration 2-Pole Motor
Motor Speed Approx. 2900 rpm at 50 Hz
Application Clean-Water Transfer / Circulation
Installation Horizontal
Liquid Clean Water / Similar Liquids
Pump Duty Continuous Industrial / Commercial Applications
Construction Heavy-Duty Industrial Construction
Mounting Base Mounted
Motor 3-Phase Industrial Motor
Suitable Industries Industrial, Commercial, Irrigation, Building Services

The model number itself provides useful dimensional information: 125-100 corresponds to the nominal suction/discharge connection sizes, while 160/176 identifies the impeller diameter range. The final “-2” denotes the 2-pole/high-speed configuration.

LEO's industrial pump range includes dedicated LEP end-suction centrifugal pumps, while the LEZ 125-100-160/176-2 is specifically listed by Malaysian LEO distributors as an industrial end-suction centrifugal model.

End-Suction Centrifugal Design

The LEZ 125-100-160/176-2 uses a conventional end-suction centrifugal configuration.

Water enters axially through the suction side of the pump and is accelerated by the rotating impeller before being discharged through the outlet.

This arrangement provides several advantages:

  • Simple hydraulic layout
  • High-volume water handling
  • Easy connection to standard pipework
  • Convenient maintenance access
  • Suitable for continuous-duty operation
  • Suitable for industrial water systems
  • Compatible with motor/base-frame installations

The design is particularly appropriate for systems requiring substantial water movement rather than extremely high pressure.

DN125 Suction / DN100 Discharge

The 125-100 designation indicates the nominal connection arrangement:

  • DN125 suction
  • DN100 discharge

The relatively large suction and discharge connections allow the pump to handle substantially greater water volume than smaller domestic centrifugal pumps.

Correct pipe sizing is important to minimize hydraulic losses.

The suction line should generally be:

  • Short
  • Straight
  • Properly supported
  • Appropriately sized
  • Free from unnecessary restrictions

Avoid reducing the suction pipe immediately before the pump unless the hydraulic design specifically requires it.

160 / 176 mm Impeller

The 160/176 designation refers to the pump's impeller diameter configuration.

The pump can therefore be selected or configured around the applicable impeller diameter to achieve the required hydraulic duty.

In centrifugal pump selection, impeller diameter has a direct influence on:

  • Head
  • Flow
  • Pump power
  • Efficiency
  • Operating point

A larger impeller generally provides greater head at a given speed, while an appropriately trimmed impeller can be used where lower head is required.

For a specific installation, the correct impeller diameter should always be selected using the manufacturer's performance curve.

2-Pole High-Speed Configuration

The final “-2” in the model designation indicates a 2-pole motor configuration.

At 50 Hz, a typical 2-pole induction motor operates at approximately 2900 rpm under load, depending on motor slip.

The high rotational speed allows the pump to achieve substantial hydraulic performance from a relatively compact impeller.

The 2-pole configuration is suitable for applications where:

  • High flow is required
  • Compact pump dimensions are preferred
  • Higher rotational speed is appropriate
  • Industrial continuous operation is required

High-Volume Water Transfer

The LEZ 125-100-160/176-2 is designed for high-capacity water movement.

Typical applications include:

  • Industrial water transfer
  • Building water circulation
  • Irrigation systems
  • Cooling-water circulation
  • General water supply
  • Water treatment systems
  • Factory process-water circulation
  • Commercial water systems
  • Tank-to-tank transfer
  • Municipal water applications

The actual flow rate and head must be selected according to the system curve and manufacturer's pump performance curve.

Industrial Water Supply

The pump is suitable for industrial water-supply systems where reliable continuous water movement is required.

Possible applications include:

  • Factory water supply
  • Production-line water circulation
  • Industrial cooling systems
  • Process-water transfer
  • Storage tank transfer
  • General plant water systems

For industrial installations, the pump should be correctly matched to the required duty point to prevent operation outside the recommended operating range.

Irrigation Applications

The high-capacity configuration also makes the LEZ suitable for selected agricultural and commercial irrigation systems.

Potential applications include:

  • Farm irrigation
  • Plantation irrigation
  • Large sprinkler systems
  • Agricultural water transfer
  • Reservoir distribution
  • Water-storage systems
  • Irrigation pumping stations

The large DN125 suction and DN100 discharge connections are particularly useful in larger irrigation installations where high water volume is required.

Building Services

The pump can be used in commercial and building-service water systems where the hydraulic requirements are within its performance range.

Possible uses include:

  • Commercial water circulation
  • Water transfer
  • Cooling-water systems
  • HVAC circulation
  • Tank filling
  • General building water systems

LEO's broader centrifugal-pump portfolio includes pumps for industrial and building water applications, including circulation and pressurization systems.

Suitable Liquids

The pump is primarily intended for clean water and liquids with physical and chemical characteristics similar to water.

Suitable fluids may include:

  • Fresh water
  • Treated water
  • Cooling water
  • Irrigation water
  • Industrial service water
  • Filtered process water

The liquid should not contain excessive abrasive particles or fibrous materials unless the specific pump configuration is approved for such service.

For chemically aggressive liquids, the seal and wetted-component materials must be verified before use.

Continuous-Duty Operation

The industrial construction of this class of pump makes it suitable for continuous or extended operating periods when correctly installed.

For continuous-duty systems, attention should be given to:

  • Correct pump sizing
  • Motor protection
  • Shaft alignment
  • Bearing condition
  • Mechanical seal condition
  • Adequate suction conditions
  • Correct operating temperature
  • Proper foundation
  • Correct coupling alignment

Operating continuously far outside the recommended performance range can cause premature wear and increased energy consumption.

Mechanical Seal

The mechanical seal prevents water from escaping along the rotating shaft.

Correct seal selection depends on:

  • Liquid temperature
  • Liquid chemistry
  • Operating pressure
  • Pump speed
  • Water quality

For clean-water service, a standard mechanical-seal arrangement is normally suitable, subject to the manufacturer's specified materials.

Never operate the pump dry, as dry running can rapidly damage the mechanical seal.

Motor and Drive

The LEZ 125-100-160/176-2 is intended for connection to an industrial motor/drive assembly.

For a typical 50 Hz installation, the 2-pole configuration operates at approximately 2900 rpm.

A correctly selected three-phase motor should include appropriate:

  • Overload protection
  • Short-circuit protection
  • Phase-loss protection
  • Earthing
  • Isolation
  • Correct cable sizing

Motor power must be selected according to the actual pump duty point rather than based solely on the maximum possible flow.

Pump Performance Selection

The most important factors when selecting the LEZ 125-100-160/176-2 are:

Required Flow (Q)
The volume of water required, normally expressed in m³/h.

Total Dynamic Head (H)
The total pressure requirement including static elevation, pipe friction and required discharge pressure.

Operating Speed
The 2-pole configuration determines the approximate operating speed.

Impeller Diameter
The applicable impeller diameter determines the pump's hydraulic performance.

Liquid Characteristics
Temperature, viscosity, solids content and chemical properties affect pump selection.

System Head Calculation

Before installation, calculate:

Total Dynamic Head = Static Head + Pipe Friction + Fitting Losses + Required Outlet Pressure

For example, a system transferring water to an elevated tank must account for:

  • Vertical height
  • Horizontal pipe length
  • Elbows
  • Valves
  • Check valves
  • Filters
  • Pipe diameter
  • Tank inlet losses

Selecting the pump only according to pipe size is not sufficient.

NPSH and Suction Conditions

For a large end-suction centrifugal pump, adequate Net Positive Suction Head Available (NPSHA) is essential.

Poor suction conditions can cause cavitation.

Symptoms of cavitation may include:

  • Unusual noise
  • Vibration
  • Reduced flow
  • Reduced pressure
  • Impeller damage
  • Premature bearing/seal failure

To improve suction conditions:

  • Keep suction piping short.
  • Avoid unnecessary elbows.
  • Use an appropriately sized suction pipe.
  • Minimize suction-side restrictions.
  • Ensure adequate water level.
  • Avoid excessive suction lift.
  • Keep the suction line free from air leaks.

Base-Mounted Installation

Unlike compact domestic close-coupled pumps, industrial end-suction pumps are commonly installed on a rigid base/foundation.

A proper installation should provide:

  • Level foundation
  • Adequate structural support
  • Correct shaft alignment
  • Proper pipe support
  • Flexible coupling where applicable
  • Suitable guards around rotating components

Pipework should never be allowed to place excessive mechanical load on the pump casing.

Maintenance

Routine maintenance should include inspection of:

  • Mechanical seal
  • Bearings
  • Coupling
  • Motor
  • Pump shaft
  • Impeller
  • Casing
  • Foundation bolts
  • Pipe connections

Monitor:

  • Pump vibration
  • Motor temperature
  • Bearing noise
  • Discharge pressure
  • Flow rate
  • Motor current

A change in normal operating conditions can indicate wear, blockage, cavitation or system changes.

Typical Applications

The LEO LEZ 125-100-160/176-2 is suitable for:

  1. Industrial water transfer
  2. Commercial water supply
  3. Agricultural irrigation
  4. Large sprinkler systems
  5. Factory cooling-water circulation
  6. HVAC water circulation
  7. Water treatment systems
  8. Tank-to-tank water transfer
  9. Industrial process-water circulation
  10. Building-service water systems
  11. Reservoir pumping
  12. General clean-water pumping
  13. Water conservation projects
  14. Industrial utility-water systems

Key Advantages

The LEO LEZ 125-100-160/176-2 offers:

  • Heavy-duty end-suction centrifugal design
  • Large DN125 suction connection
  • DN100 discharge connection
  • 160/176 mm impeller configuration
  • 2-pole high-speed configuration
  • Suitable for high-volume water transfer
  • Suitable for industrial applications
  • Suitable for irrigation
  • Suitable for commercial water systems
  • Suitable for water circulation
  • Suitable for tank transfer
  • Suitable for building services
  • Base-mounted industrial configuration
  • Serviceable centrifugal-pump construction
  • Suitable for clean water and similar liquids

Important Specification Note

For this particular LEZ 125-100-160/176-2, publicly indexed sources confirm the model and its classification as an LEO end-suction centrifugal pump, but I could not verify a reliable manufacturer-published performance table for this exact model from the available sources. The model is listed by Malaysian LEO distributors under industrial centrifugal pumps.

Therefore, values such as exact motor kW, rated flow, rated head, efficiency, impeller trim and NPSHr should be taken from the pump nameplate or LEO's specific performance curve, rather than inserting an unverified figure into the product listing.

Product Description

LEO LEZ 125-100-160/176-2 End Suction Centrifugal Pump is a heavy-duty industrial water pump designed for high-volume clean-water transfer, industrial water supply, irrigation, commercial water systems, cooling-water circulation, building services and general water-transfer applications. The pump features a conventional end-suction centrifugal configuration, large DN125 suction and DN100 discharge connections, a 160/176 mm impeller configuration and a 2-pole high-speed drive arrangement.

Its large hydraulic connections and industrial configuration make it suitable for demanding applications requiring reliable and continuous water movement. The pump can be integrated into industrial pipework, irrigation networks, water-treatment systems, commercial water supplies, tank-transfer systems and circulation systems.

For accurate pump selection, the required flow rate, total dynamic head, impeller diameter, motor power and NPSH requirements should be checked against the manufacturer's performance curve for the specific LEZ 125-100-160/176-2 configuration.

SEO Product Title

LEO LEZ 125-100-160/176-2 End Suction Centrifugal Water Pump – Industrial Heavy Duty

Short Product Description

LEO LEZ 125-100-160/176-2 is a heavy-duty end-suction centrifugal pump designed for industrial, commercial, irrigation, water-transfer and circulation applications. Featuring DN125 suction, DN100 discharge, 160/176 mm impeller configuration and a 2-pole high-speed drive, this pump is designed for high-volume clean-water handling and continuous-duty applications. Suitable for industrial water supply, agricultural irrigation, cooling-water circulation, building services, tank transfer and general water systems.



 Inquiry - LEO END SUCTION CENTRIFUGAL PUMPS - LEZ 125-100-160/176-2