LEO CIRCULATION PUMPS - LRP 32-80/180



The LEO LRP 32-80/180 is a three-speed, single-phase circulator pump designed for continuous circulation of hot and cold water in heating, HVAC, domestic hot-water and other closed-loop water-circulation systems. It is part of LEO's LRP circulation-pump range, which is designed for heating, ventilation and air-conditioning circulation, domestic hot-water circulation, solar-heating systems and industrial auxiliary circulation.

The 32-80/180 designation indicates a nominal 32 mm pump connection size and a 180 mm installation/port-to-port length. The LRP 32-80/180 provides up to approximately 10.2 m³/h flow and 7.3 m maximum head, with three manually selectable operating speeds.

Product Specifications

Specification LEO LRP 32-80/180
Brand LEO
Model LRP 32-80/180
Product Type Circulation Pump
Pump Series LRP32
Pump Application Heating / HVAC / Hot & Cold Water Circulation
Motor Type Three-Speed Circulation Motor
Electrical Supply 220–240 V
Frequency 50 Hz
Phase Single Phase
Maximum Flow 10.2 m³/h / approx. 170 L/min
Maximum Head 7.3 m
Speed Settings 3 Speeds
Speed 1 Flow Up to approx. 167 L/min*
Speed 2 Flow Up to approx. 100 L/min*
Speed 3 Flow Up to approx. 60 L/min*
Speed 1 Head Up to approx. 7.3 m*
Speed 2 Head Up to approx. 6.7 m*
Speed 3 Head Up to approx. 5.4 m*
Maximum Fluid Temperature +110°C
Minimum Fluid Temperature +2°C
Maximum Working Pressure Up to 16 bar
Insulation Class H
Protection Class IP44
Bearing 99% Alumina Ceramic Bearing
Motor Winding Copper
Installation Length 180 mm
Connection Size DN32 / 32 mm
Installation Position Horizontal/Vertical, subject to shaft orientation
Suitable Fluid Clean Water / Water-Like Fluids

*The published LRP32 technical table lists the maximum flow figures for the three speed settings as 167/100/60 L/min and maximum heads as 7.3/6.7/5.4 m.

Product Overview

The LEO LRP 32-80/180 is designed to maintain water circulation within a piping system rather than to transfer water from one source to another. It is therefore particularly suitable for closed-loop heating and cooling systems, where maintaining adequate circulation is essential for consistent heat distribution.

The pump uses a three-speed motor, allowing the installer or operator to manually select the appropriate circulation level. This makes it possible to balance circulation performance against electrical consumption and system requirements.

With a maximum head of approximately 7.3 m and maximum flow of approximately 10.2 m³/h, the LRP 32-80/180 is intended for medium-duty circulation requirements within its hydraulic performance range.

Key Features

Three-Speed Operation

The LRP 32-80/180 has three selectable speed levels. The three settings provide different combinations of flow and head, allowing the pump to be matched more closely to the hydraulic requirements of the system. The published performance figures are approximately:

  • Speed 1: 167 L/min, maximum head 7.3 m
  • Speed 2: 100 L/min, maximum head 6.7 m
  • Speed 3: 60 L/min, maximum head 5.4 m

The actual operating point will depend on the system resistance and should be determined from the pump curve.

High-Temperature Water Circulation

The LRP series is designed for both cold- and hot-water circulation. Published operating conditions specify a liquid temperature range of approximately 2°C to 110°C, making the pump suitable for many heating and domestic hot-water circulation applications.

High-Temperature Motor Insulation

The motor uses Class H insulation, providing a high thermal insulation rating appropriate for circulation-pump applications involving elevated ambient and fluid temperatures.

IP44 Protection

The motor is specified with IP44 protection, providing protection against solid objects of relevant size and splashing water from all directions.

Ceramic Bearing

The LRP series uses a 99% alumina ceramic bearing, a material commonly used in wet-rotor circulation pumps because of its suitability for continuous operation in water-circulation environments.

Copper Motor Winding

The motor is specified with copper windings, supporting reliable electrical and thermal performance during circulation operation.

180 mm Installation Length

The 180 mm installation length is an important replacement consideration. The pump should be matched to the existing pipework and mounting arrangement to ensure correct installation without modifying the system unnecessarily.

Performance

The LRP 32-80/180 has a published maximum performance of approximately:

Maximum flow: 10.2 m³/h
Maximum flow equivalent: approximately 170 L/min
Maximum head: 7.3 m

The three speed settings provide different performance characteristics. The published LRP32 table gives:

Speed Maximum Flow Maximum Head
Speed 1 167 L/min 7.3 m
Speed 2 100 L/min 6.7 m
Speed 3 60 L/min 5.4 m

 

These are maximum curve values and should not be treated as simultaneous flow-and-head operating points. For example, achieving the maximum 7.3 m head does not mean the pump will simultaneously deliver 167 L/min.

For proper pump selection, the required flow rate and total dynamic head should be determined first, then compared with the LRP 32-80/180 pump curve.

Recommended Applications

The LEO LRP 32-80/180 is suitable for:

  • Central heating circulation
  • Residential heating systems
  • Commercial building heating systems
  • HVAC circulation
  • Hot-water circulation
  • Cold-water circulation
  • Domestic hot-water systems
  • Solar hot-water circulation
  • District heating systems
  • Radiator heating systems
  • Underfloor heating circulation
  • Industrial auxiliary hot-water circulation
  • Industrial auxiliary cold-water circulation
  • Closed-loop water circulation systems

LEO specifically lists HVAC circulation, domestic hot-water pressure/circulation, solar-powered hot-water systems, industrial auxiliary hot- and cold-water circulation, central and district heating systems and domestic hot-water circulation among the applications for the LRP range.

Suitable Fluid

The LRP 32-80/180 is designed primarily for clean water and liquids with properties similar to water.

The circulating fluid should generally be:

  • Clean
  • Non-abrasive
  • Non-corrosive to the pump materials
  • Non-viscous
  • Free from large suspended solids
  • Chemically compatible with the pump

It is not intended as a sewage, slurry, abrasive-fluid or solids-handling pump.

Operating Conditions

Published LRP32 operating conditions include:

  • Fluid temperature: approximately 2°C to +110°C
  • Maximum ambient temperature: up to +40°C
  • Maximum system pressure: up to 16 bar
  • Maximum installation altitude: approximately 1,000 m above sea level

These limits are important when using the pump in high-temperature heating systems or pressurised circulation loops.

Installation

The LRP 32-80/180 is intended for installation directly into the circulation pipework. As a wet-rotor circulation pump, correct orientation is important.

The motor shaft should be positioned horizontally during installation so that the internal bearing and rotor assembly receive the correct lubrication from the circulating fluid.

Before installation:

  1. Confirm that the pump connection size matches the system.
  2. Confirm the required 180 mm installation length.
  3. Flush the pipework to remove debris.
  4. Install appropriate isolation valves where required.
  5. Ensure the pump is installed in the correct flow direction.
  6. Fill and vent the system before operation.
  7. Remove trapped air from the pump/system.
  8. Select the appropriate speed setting after commissioning.

The pump should not be allowed to run without the required circulating fluid.

Advantages of LEO LRP 32-80/180

  1. Three-speed operation for adjustable circulation performance.
  2. 7.3 m maximum head for medium-duty heating and circulation systems.
  3. Up to approximately 10.2 m³/h flow for substantial circulation requirements.
  4. 180 mm installation length suitable for many standard circulation-pump replacements.
  5. 220–240 V single-phase supply for convenient electrical installation.
  6. Class H insulation for high-temperature operating environments.
  7. IP44 motor protection for circulation-system installations.
  8. Ceramic bearing construction designed for wet-rotor operation.
  9. Copper motor winding for reliable motor performance.
  10. Suitable for hot and cold water circulation.
  11. Suitable for HVAC and heating applications.
  12. Suitable for domestic and commercial circulation systems.

Important Selection Note

The LRP 32-80/180 should not be selected solely because the system requires a maximum head of 7.3 m or a maximum flow of 10.2 m³/h. These are maximum published values.

For correct selection, determine:

Required flow rate (Q) + required total head (H) + fluid temperature + system pressure + pipe connection/installation length.

The operating point should fall within the pump's useful hydraulic curve. This is particularly important in heating systems because an oversized circulation pump can result in excessive flow, noise and unnecessary energy consumption, while an undersized pump may not provide adequate heat distribution.

Website Product Description

LEO LRP 32-80/180 Circulation Pump is a high-performance three-speed circulator designed for heating, HVAC, domestic hot-water and general hot- and cold-water circulation systems. Operating on 220–240 V single-phase power, the LRP 32-80/180 provides up to approximately 10.2 m³/h flow and 7.3 m maximum head, with three manually selectable speed settings for flexible system balancing.

The pump is designed for circulating clean water and compatible water-like fluids at temperatures from approximately 2°C to 110°C and system pressures up to 16 bar. It features Class H motor insulation, IP44 protection, copper motor windings and a 99% alumina ceramic bearing, providing a robust configuration for continuous circulation duty.

With an 180 mm installation length and 32 mm nominal connection size, the LEO LRP 32-80/180 is suitable for a wide range of residential and commercial heating installations. Typical applications include central heating, radiator systems, underfloor heating, HVAC circulation, domestic hot-water circulation, solar water-heating systems, district heating and industrial auxiliary hot- and cold-water circulation.

SEO Product Title

LEO LRP 32-80/180 Circulation Pump 220-240V 3-Speed 7.3m Head 180mm

SEO Meta Description

LEO LRP 32-80/180 circulation pump with 3-speed motor, 7.3m maximum head and up to 10.2m³/h flow. Suitable for heating, HVAC, hot-water and domestic circulation systems.



 Inquiry - LEO CIRCULATION PUMPS - LRP 32-80/180