The LEO LRP 40-80F/250 is a three-speed flanged circulation pump designed for circulating hot and cold water in heating, HVAC, domestic hot-water and industrial auxiliary systems. It is intended for continuous circulation rather than conventional water transfer and is particularly suitable for central heating, district heating, HVAC circulation and domestic hot-water systems. LEO lists the LRP series for HVAC circulation, hot-water pressure boosting, solar-heated homes, industrial auxiliary circulation and central/district heating.
The 40-80F/250 designation identifies a DN40 flanged connection with a 250 mm installation length. The model has a maximum flow of approximately 170 L/min (10.2 m³/h) and maximum head of 7.3 m. Its three selectable speeds allow the circulation performance to be adjusted to suit different system requirements.
Product Specifications
| Specification | LEO LRP 40-80F/250 |
|---|---|
| Brand | LEO |
| Model | LRP 40-80F/250 |
| Product Type | Flanged Circulation Pump |
| Pump Series | LRP |
| Pump Configuration | Three-Speed Circulator |
| Motor Type | Single Phase |
| Voltage | 220–240 V |
| Frequency | 50 Hz |
| Rated Power | 270 W |
| Maximum Flow | 170 L/min / 10.2 m³/h |
| Maximum Head | 7.3 m |
| Speed Settings | 3 |
| Speed 1 Maximum Flow | 170 L/min |
| Speed 2 Maximum Flow | 113 L/min |
| Speed 3 Maximum Flow | 65 L/min |
| Speed 1 Maximum Head | 7.3 m |
| Speed 2 Maximum Head | 6.7 m |
| Speed 3 Maximum Head | 5.4 m |
| Connection Type | Flanged |
| Nominal Connection | DN40 |
| Pipe Size | Approx. 1½" / 1¾" class |
| Installation Length | 250 mm |
| Maximum Liquid Temperature | 110°C |
| Minimum Liquid Temperature | 2°C |
| Motor Insulation Class | H |
| Protection Class | IP44 |
| Shaft | 99% Alumina Ceramic |
| Bearing | Ceramic / Graphite Construction |
| Impeller | Noryl |
| Pump Body | Bronze or Anti-Rust Cast Iron |
| Motor Winding | Copper |
| Main Application | Heating / HVAC / Hot & Cold Water Circulation |
The model-specific technical table lists 270 W power, 170/113/65 L/min maximum flows and 7.3/6.7/5.4 m maximum heads for speeds 1/2/3, respectively. The published dimensional drawing gives a 250 mm installation length for LRP40-80F/250.
Product Overview
The LEO LRP 40-80F/250 is a larger-capacity member of the LRP circulation-pump range, intended for systems requiring more circulation capacity than smaller threaded LRP models.
Unlike a standard centrifugal transfer pump, a circulation pump is installed directly into the piping loop and continuously moves water around the system. This makes the LRP 40-80F/250 particularly appropriate for closed-loop heating and cooling systems, where maintaining the required flow through radiators, heat exchangers, boilers or HVAC circuits is important.
The pump operates with three manually selectable speeds, allowing the system operator to choose an appropriate hydraulic operating level.
Three-Speed Operation
One of the main features of the LRP 40-80F/250 is its three-speed motor.
The published performance values are approximately:
| Speed | Maximum Flow | Maximum Head |
|---|---|---|
| Speed 1 | 170 L/min | 7.3 m |
| Speed 2 | 113 L/min | 6.7 m |
| Speed 3 | 65 L/min | 5.4 m |
These are maximum curve values rather than simultaneous operating points. For example, the pump does not deliver 170 L/min at 7.3 m head simultaneously.
The actual operating point depends on the hydraulic resistance of the connected system.
270 W Motor
The LRP 40-80F/250 is specified with a 270 W motor and operates from a 220–240 V, 50 Hz single-phase supply. This makes it suitable for many residential, commercial and light industrial circulation installations without requiring a three-phase electrical supply.
The motor incorporates Class H insulation, IP44 protection and copper windings, according to LEO's LRP-series specifications.
High-Temperature Circulation
The pump is designed for circulating both cold and hot water. The published operating range for the LRP series is approximately 2°C to +110°C. The Noryl impeller is specified with heat resistance up to approximately 150°C, although the actual allowable pumped-liquid temperature remains governed by the complete pump specification.
This makes the pump suitable for applications such as:
- Hot-water heating
- Radiator circulation
- Central heating
- District heating
- HVAC water circulation
- Domestic hot-water circulation
- Solar-heating circulation
- Industrial hot-water circulation
Flanged Connection
The "F" in LRP 40-80F/250 denotes the flanged configuration. This differentiates it from smaller threaded circulation-pump models.
The LRP 40-80F/250 has:
- DN40 nominal connection
- 250 mm installation length
- Flanged pipe connections
- Approximately 150 mm flange outer diameter
- Approximately 110 mm bolt-circle diameter
- 11 mm flange-hole diameter
The published dimensional drawing gives these dimensions for the LRP40-80F/250.
When replacing an existing circulation pump, the 250 mm face-to-face installation length and flange dimensions should be checked carefully before ordering.
Pump Construction
The LRP series uses materials selected for hot- and cold-water circulation applications.
Pump Body:
LEO specifies a bronze or anti-rust cast-iron pump body, depending on the particular configuration.
Impeller:
The impeller is manufactured from Noryl, with published heat resistance up to approximately 150°C. Noryl provides a lightweight, corrosion-resistant construction suitable for water circulation.
Shaft:
The shaft is specified as 99% alumina ceramic, a material commonly used in wet-rotor circulation pumps because of its wear resistance and suitability for water-lubricated operation.
Bearing:
The LRP series uses ceramic/graphite bearing components designed for circulation-pump operation.
Recommended Applications
The LEO LRP 40-80F/250 is suitable for:
- Central heating systems
- District heating systems
- Radiator heating systems
- HVAC circulation
- Chilled-water circulation
- Hot-water circulation
- Domestic hot-water systems
- Solar hot-water systems
- Boiler circulation
- Heat-exchanger circulation
- Commercial building heating
- Industrial auxiliary hot-water circulation
- Industrial auxiliary cold-water circulation
- Closed-loop heating systems
- Closed-loop cooling systems
LEO specifically identifies the LRP series for HVAC circulation, domestic hot-water circulation, central and district heating, solar-powered hot-water systems and industrial auxiliary hot/cold-water circulation.
Suitable Fluid
The LRP 40-80F/250 is intended primarily for clean water and compatible water-like liquids.
Suitable applications generally include:
- Clean heating water
- Clean chilled water
- Domestic hot water
- Treated circulating water
- Compatible water/glycol systems where permitted by the manufacturer's specifications
The pump should not be used for abrasive slurry, sewage, heavily contaminated water or liquids containing large quantities of suspended solids unless the manufacturer specifically approves the application.
Operating Conditions
Important operating limits include:
Liquid temperature: approximately 2°C to 110°C
Electrical supply: 220–240 V / 50 Hz
Motor insulation: Class H
Motor protection: IP44
The LRP series is therefore suited to elevated-temperature circulation duties while maintaining the compact configuration associated with conventional three-speed circulators.
Installation Considerations
The LRP 40-80F/250 should be installed directly into the circulation pipeline with the 250 mm installation length and correct DN40 flange arrangement.
For reliable operation:
- Check that the existing pipework and flange dimensions match the pump.
- Install the pump in the correct flow direction.
- Ensure the pump shaft is positioned correctly according to the manufacturer's installation requirements.
- Flush the pipework before commissioning.
- Remove air from the system before operation.
- Ensure adequate water is present in the circulation loop.
- Select the appropriate speed setting.
- Check for leakage around the flange connections after commissioning.
The pump should not be operated without the circulating liquid required for lubrication and cooling of its internal wet-rotor components.
Advantages of LEO LRP 40-80F/250
- Three-speed operation for flexible system adjustment.
- 270 W motor suitable for medium-duty circulation.
- Maximum 170 L/min flow for substantial heating and HVAC loops.
- Maximum 7.3 m head for useful circulation pressure.
- DN40 flanged construction for larger pipework.
- 250 mm installation length for compatible replacement applications.
- 220–240 V single-phase operation.
- Class H insulation for high-temperature applications.
- IP44 protection for circulation-system environments.
- Noryl impeller with high-temperature resistance.
- 99% alumina ceramic shaft for wet-rotor operation.
- Suitable for hot and cold water circulation.
- Suitable for heating and HVAC systems.
- Suitable for domestic and industrial auxiliary circulation.
Pump Selection
The LRP 40-80F/250 should be selected according to the actual flow rate and required head, not simply according to the maximum specifications.
For example, a heating system may require a specific flow through the boiler or heat exchanger. The pump must overcome the friction losses through:
- Pipes
- Elbows
- Valves
- Heat exchangers
- Radiators
- Filters
- Control valves
- Other system components
The required duty point should then be compared with the LRP 40-80F/250 performance curve.
An oversized circulation pump can cause excessive flow velocity, pipe noise and unnecessary energy consumption, while an undersized pump may result in inadequate heat transfer or insufficient circulation.
Website Product Description
LEO LRP 40-80F/250 Circulation Pump 270W 220-240V is a three-speed flanged circulation pump designed for heating, HVAC, domestic hot-water and industrial water-circulation systems. With a 270 W single-phase motor, the LRP 40-80F/250 provides up to approximately 170 L/min (10.2 m³/h) flow and 7.3 m maximum head, making it suitable for medium-duty circulation applications.
The pump features three selectable speed settings, allowing circulation performance to be adjusted according to the hydraulic requirements of the system. Maximum published performance is approximately 170/113/65 L/min with corresponding maximum heads of 7.3/6.7/5.4 m for speeds 1, 2 and 3.
The LRP 40-80F/250 is constructed with a bronze or anti-rust cast-iron pump body, Noryl impeller, 99% alumina ceramic shaft, ceramic/graphite bearing construction, copper motor winding, Class H insulation and IP44 motor protection. It is designed for circulating water at approximately 2°C to 110°C.
With its DN40 flanged connections and 250 mm installation length, the LEO LRP 40-80F/250 is suitable for central heating, district heating, radiator systems, HVAC circulation, domestic hot-water circulation, solar heating, boiler systems, heat exchangers and industrial auxiliary hot- and cold-water circulation.
SEO Product Title
LEO LRP 40-80F/250 Circulation Pump 270W 220-240V 3-Speed DN40 Flange 250mm
SEO Meta Description
LEO LRP 40-80F/250 270W three-speed flanged circulation pump with 7.3m maximum head and 170L/min flow. Ideal for heating, HVAC, hot-water and industrial circulation systems.
Inquiry - LEO CIRCULATION PUMPS - LRP 40-80F/250