B116, C15 Jalan Haji Ahmad, Perkampungan Seri Setali, 25300 Kuantan, Pahang, Malaysia.

+6019-323 7617

kstoolsdepot@gmail.com


Share:


LEO SEWAGE SUBMERSIBLE PUMPS - 100 WQ 65-15-5.5 T/QG



The LEO 100 WQ 65-15-5.5 T/QG is a heavy-duty three-phase submersible sewage pump with cutter/grinder system, designed for high-volume wastewater, sewage, industrial drainage and dewatering applications. It is equipped with a 5.5 kW / 7.5 HP motor, 4-inch (100 mm) discharge, and operates at 3,000 RPM. Published LEO-series specifications give a maximum flow of approximately 1,333.3 L/min (80 m³/h) and maximum head of 32 m.

The T/QG configuration is particularly suited to sewage applications where fibrous or organic materials may create clogging problems, as the cutter system helps process suitable solids before discharge.

Product Specifications

Specification Details
Brand LEO
Series WQ Sewage Submersible Pump
Model 100 WQ 65-15-5.5 T/QG
Pump Type Submersible Sewage Pump with Cutter
Motor Power 5.5 kW / 7.5 HP
Voltage 415 V
Frequency 50 Hz
Phase 3 Phase
Motor Speed 3,000 RPM
Discharge Size 4" / 100 mm
Nominal Flow Approx. 65 m³/h
Nominal Head Approx. 15 m
Maximum Flow 1,333.3 L/min / approx. 80 m³/h
Maximum Head 32 m
Motor Winding Copper
Insulation Class F
Protection Class IP68
Mechanical Seal Dual Mechanical Seal
Impeller Cutter / Grinder Type
Leak Protection Leak-proof detector
Cooling / Protection Oil Jacket
Maximum Liquid Temperature 40°C
Permitted pH 4–10
Cable Length 10 m
Connection Hose Coupler
Auto-Float Switch Not included
Approx. Gross Weight 84 kg
Packing Dimensions Approx. 904 × 399 × 439 mm

The Malaysian LEO WQ-series specification table identifies the 100WQ65-15-5.5T/QG as a 415 V, 5.5 kW / 7.5 HP, 4-inch pump with maximum flow of 1,333.3 L/min, maximum head of 32 m, and speed of 3,000 RPM.

Key Features

5.5 kW / 7.5 HP three-phase motor:
The powerful motor provides the output required for high-volume sewage pumping, industrial wastewater transfer and demanding drainage applications.

High-flow capacity:
With a maximum flow of approximately 1,333.3 L/min, equivalent to about 80 m³/h, this pump is designed for moving large quantities of wastewater efficiently.

High pumping head:
The pump has a published maximum head of 32 m, providing substantial vertical lifting capability for drainage systems with significant elevation differences.

4-inch discharge outlet:
The 100 mm / 4-inch discharge provides a large flow passage appropriate for high-volume wastewater and sewage applications.

Cutter/grinder configuration:
The QG system is designed for sewage containing suitable fibrous and organic matter. The cutting action helps reduce the size of materials that could otherwise contribute to pipe or impeller blockage.

Heavy-duty submersible construction:
The pump is designed to operate while submerged, allowing direct installation in sewage pits, wastewater tanks, sumps and drainage collection areas.

IP68 motor enclosure:
The motor is designed for demanding wet and submerged environments. The published model specification identifies an IP68 enclosure/protection class.

Copper motor winding:
The motor uses copper winding and Class F insulation for reliable operation under demanding pumping conditions.

Dual mechanical seal:
The double mechanical sealing arrangement helps prevent wastewater from entering the motor chamber and protects the internal motor components.

Oil-jacket construction:
The oil-jacket design provides additional protection around the sealing area and assists with heat management during operation.

Leak-proof detector:
The pump incorporates a leak-protection detection arrangement to provide additional protection against water ingress into the motor section.

Performance Information

Performance Parameter Specification
Motor Power 5.5 kW
Motor Rating 7.5 HP
Nominal Flow Approx. 65 m³/h
Nominal Head Approx. 15 m
Maximum Flow Approx. 80 m³/h
Maximum Flow 1,333.3 L/min
Maximum Head 32 m
Discharge 4" / 100 mm
Speed 3,000 RPM
Voltage 415 V
Frequency 50 Hz
Phase 3 Phase

The model number 65-15 corresponds to the pump's nominal flow/head designation, while the published hydraulic limit is approximately 80 m³/h maximum flow and 32 m maximum head. These maximum values should not be interpreted as simultaneous operating points.

Operating Conditions

The LEO WQ sewage pump range is intended for demanding wastewater environments. Published specifications include a maximum liquid temperature of 40°C, liquid pH range of 4–10, copper motor winding, Class F insulation and IP68 motor protection.

For the 5.5 kW and above WQ range, LEO indicates that a control cabinet is required, with the motor using a delta connection for the applicable power range.

Typical Applications

The LEO 100 WQ 65-15-5.5 T/QG is suitable for:

  • Industrial sewage pumping
  • Factory wastewater drainage
  • Construction-site dewatering
  • Commercial wastewater systems
  • Municipal sewage treatment plants
  • Sewage collection stations
  • Residential drainage stations
  • Wastewater storage tanks
  • Drainage pits and sumps
  • Underground and basement drainage
  • Municipal drainage projects
  • Agricultural wastewater drainage
  • Methane/biogas pool drainage
  • Floodwater removal
  • High-volume dirty-water transfer

LEO identifies factories, construction sites, commercial facilities, municipal sewage treatment plants, residential drainage stations, municipal projects, methane pools and countryside field irrigation among the applications of its WQ submersible sewage pump range.

Cutter Pump Advantage

The T/QG version is designed for wastewater applications where conventional pumps may experience clogging from fibrous or organic materials.

The cutter system helps break down suitable materials before they enter the discharge line, making this configuration appropriate for sewage and contaminated wastewater containing materials such as:

  • Fibrous waste
  • Organic matter
  • Paper-type waste
  • Sewage solids
  • Long-string materials

The cutter system does not mean the pump is suitable for all hard, abrasive or oversized solids. Actual wastewater characteristics should be checked against the manufacturer's permitted operating conditions.

Construction & Protection

The pump incorporates several features intended for harsh sewage environments:

  • Heavy-duty submersible construction
  • Cutter/grinder system
  • 4-inch discharge
  • Copper motor winding
  • Class F insulation
  • IP68 motor protection
  • Dual mechanical seal
  • Oil-jacket protection
  • Leak-proof detector
  • 10 m power cable
  • Hose-coupler connection
  • Three-phase motor

LEO's general WQ documentation also specifies double-end mechanical seals, ball bearings and a stainless-steel welded shaft for the WQ series.

Dimensions & Weight

Published product information gives the following approximate shipping details for the 100 WQ 65-15-5.5 T/QG:

Packing dimensions: 904 × 399 × 439 mm
Gross weight: approximately 84 kg

A LEO technical catalogue gives approximately 685 mm overall height for the corresponding 100WQ65-15-5.5T/QG configuration, with a 100 mm discharge dimension.

Actual installation dimensions should be checked against the pump's supplied technical drawing before fabrication of guide rails, discharge piping or mounting arrangements.

Model Number Explanation

100 WQ 65-15-5.5 T/QG

  • 100 – 100 mm / 4-inch discharge class
  • WQ – LEO submersible sewage/wastewater pump series
  • 65 – nominal flow designation, approximately 65 m³/h
  • 15 – nominal head designation, approximately 15 m
  • 5.5 – 5.5 kW motor power
  • T – three-phase configuration
  • QG – cutter/grinder sewage-pump configuration

Installation Considerations

This model is a 415 V three-phase, 5.5 kW pump and should be installed with suitable electrical protection and a properly rated control cabinet.

For reliable operation:

  • Do not operate the pump dry.
  • Ensure sufficient liquid covers the pump before starting.
  • Use correctly sized 4-inch discharge piping.
  • Install suitable overload and short-circuit protection.
  • Verify correct phase rotation.
  • Check the mechanical seal and power cable before installation.
  • Ensure the wastewater temperature and pH remain within the permitted range.
  • Avoid operating outside the pump's hydraulic duty range.
  • Provide adequate lifting equipment because the pump weighs approximately 84 kg gross when packed.
  • Follow the manufacturer's installation and maintenance instructions.

SEO Product Description

LEO 100 WQ 65-15-5.5 T/QG 7.5HP 5.5kW 4" Three Phase Cutter Sewage Submersible Pump is a heavy-duty wastewater and sewage pump designed for high-volume drainage, industrial wastewater transfer, construction dewatering and municipal sewage applications. Powered by a 5.5 kW / 7.5 HP three-phase motor, it delivers a maximum flow of approximately 1,333.3 L/min (80 m³/h) and a maximum head of 32 m. The pump features a 4-inch discharge, cutter/grinder system, IP68 protection, copper motor winding, Class F insulation, dual mechanical seal, oil-jacket protection and leak-proof detector for demanding wastewater environments. Its robust submersible design makes it suitable for factories, construction sites, commercial facilities, sewage treatment plants, drainage stations and other wastewater management systems.

Recommended Product Title

LEO 100 WQ 65-15-5.5 T/QG 7.5HP 5.5kW 4" Three Phase Cutter Sewage Submersible Pump

Short Product Description

LEO 100 WQ 65-15-5.5 T/QG is a 7.5 HP / 5.5 kW three-phase cutter sewage submersible pump with a 4-inch discharge. It provides a maximum flow of approximately 1,333.3 L/min (80 m³/h) and maximum head of 32 m. Designed for heavy-duty sewage, wastewater, industrial drainage and dewatering applications, it features IP68 protection, dual mechanical seals, copper motor winding, oil-jacket protection and a cutter/grinder system for improved clogging resistance in suitable wastewater applications.



 Inquiry - LEO SEWAGE SUBMERSIBLE PUMPS - 100 WQ 65-15-5.5 T/QG