SATA 12KV INSULATING GLOVES FOR HIGH-VOLTAGE - AE3611



The SATA AE3611 12KV Insulating Gloves for High-Voltage Work are electrical insulating rubber gloves designed to provide protection during specified electrical maintenance and live-working applications. They are manufactured from virgin rubber with high insulation performance, combining electrical insulation with flexibility, tear resistance, aging resistance and good toughness. The gloves have a 360 mm long cuff to provide extended hand and wrist/forearm coverage. SATA specifies a verification/test voltage of AC 12,000V, while its current product page lists a maximum operating voltage of AC 7,500V.

Key Features

  • Designed for high-voltage electrical work and maintenance.
  • Made from virgin rubber with high electrical insulation performance.
  • 360 mm overall length provides extended protection beyond the hand.
  • Soft and flexible rubber construction improves hand movement during work.
  • Tear-resistant material helps withstand normal handling.
  • Aging-resistant rubber formulation supports longer service life.
  • Strong toughness helps maintain glove integrity during repeated handling.
  • Ergonomic palm-shaped design improves fit and flexibility.
  • Rubber surface is designed to resist cracking under normal conditions.
  • AC 12,000V verification/test voltage.
  • SATA product specification lists AC 7,500V maximum operating voltage.
  • Manufactured according to GB/T 17622-2008.
  • SATA documentation also references IEC 60903-2002, MOD.
  • Suitable for electricians, electrical maintenance technicians and power-equipment servicing.
  • Supplied as a pair of insulating gloves; SATA lists 14 pcs/pack in its product specification.

Technical Specifications

Specification Details
Brand SATA
Model AE3611
Product Type High-Voltage Insulating Gloves
Product Category Electrical Safety Gloves
Material Rubber / Virgin Rubber
Length 360 mm
Maximum Operating Voltage AC 7,500V
Verification Voltage AC 12,000V
Verification Duration 3 minutes
Performance Level Level 1*
Executive Standard GB/T 17622-2008
Referenced Standard IEC 60903-2002, MOD
Weight Approx. 0.37 kg
Country of Manufacture China
Warranty Consumable item; excluded from SATA lifetime warranty

*Some Malaysian distributor listings identify AE3611 as Level 1, while SATA's official product page emphasizes the voltage and material specifications.

High-Voltage Electrical Insulation

The primary function of the SATA AE3611 is to provide electrical insulation between the user's hands and electrical equipment during appropriate electrical work.

SATA specifies an AC 12,000V verification voltage with a 3-minute verification duration. The current SATA product specification separately states a maximum operating voltage of AC 7,500V. These figures should not be interpreted as meaning the gloves are intended for unrestricted work on 12kV energized systems.

For product listings, it is therefore preferable to describe the AE3611 as 12KV-tested/verified insulating gloves, while clearly stating the manufacturer's maximum operating voltage.

Virgin Rubber Construction

The gloves use virgin rubber material, selected for its electrical insulation characteristics. SATA describes the material as providing a high insulation level.

The rubber construction also provides the flexibility required for electrical maintenance work where technicians need to operate tools, switches, terminals and equipment while wearing the gloves.

360mm Extended Length

The AE3611 has an overall length of approximately 360 mm.

The extended cuff provides additional coverage beyond a conventional short work glove and helps reduce the amount of exposed skin around the wrist during electrical work.

The longer design is useful when working around:

  • Electrical panels
  • Switchgear
  • Power equipment
  • Distribution equipment
  • Electrical cabinets
  • Industrial electrical systems
  • Automotive high-voltage systems

The glove cuff should be worn correctly with appropriate sleeves and other PPE according to the applicable electrical safety procedure.

Soft and Flexible Palm Design

SATA describes the AE3611 as having a soft texture and palm-shaped design. The design is intended to improve flexibility and reduce cracking during normal use.

This is important because electrical insulating gloves need to provide protection while still allowing the wearer to:

  • Grip tools
  • Operate switches
  • Handle electrical components
  • Position test equipment
  • Perform maintenance tasks
  • Manipulate cables and connectors

Tear Resistance

The rubber formulation is designed for tear resistance and strong toughness.

This helps the gloves withstand normal handling and movement during maintenance work. However, electrical insulating gloves should never be treated as ordinary mechanical work gloves or intentionally exposed to sharp edges, abrasive surfaces or cutting hazards.

Aging Resistance

SATA specifies aging resistance as one of the material characteristics of the AE3611.

Proper storage remains essential because rubber insulating products can deteriorate when exposed to unsuitable environmental conditions, heat, sunlight, ozone, oils or chemicals.

Electrical Safety Standard

The SATA AE3611 is specified to GB/T 17622-2008, the standard stated by SATA for this product. SATA documentation also references IEC 60903-2002, MOD.

Compliance with the applicable standard does not remove the requirement for inspection, periodic electrical testing and correct PPE procedures.

Verification Voltage

The manufacturer specifies:

Verification voltage: AC 12,000V

Verification duration: 3 minutes

SATA's technical documentation also gives electrical insulation performance information, including a factory test voltage of 12 kV and specified leakage-current limits.

This verification specification is an important part of the product's electrical-insulation performance.

Maximum Operating Voltage

The current SATA product page specifies:

Maximum operating voltage: AC 7,500V.

This distinction is important. The 12,000V figure is the verification/test voltage, not the normal operating voltage.

For accurate product marketing, the recommended wording is:

12KV Verification Voltage / AC 7.5KV Maximum Operating Voltage

rather than simply claiming that the gloves are suitable for unrestricted 12kV live work.

Electrical Maintenance Applications

The AE3611 can be used as part of an appropriate electrical PPE system for specified electrical maintenance applications, including:

  • Electrical equipment servicing
  • Power distribution maintenance
  • Electrical panel work
  • Switchgear maintenance
  • Electrical cabinet servicing
  • Power equipment inspection
  • Industrial electrical maintenance
  • Electrical installation work
  • Utility maintenance
  • High-voltage equipment servicing

Actual suitability depends on the voltage, work method, applicable regulations and complete PPE system.

Automotive and EV Applications

The gloves may also be useful for technicians working on electrical and high-voltage vehicle systems where the glove specification and work procedure are appropriate.

Potential applications include:

  • High-voltage vehicle maintenance
  • EV electrical systems
  • Hybrid vehicle servicing
  • Battery system maintenance
  • High-voltage cabling
  • Electrical component inspection
  • Automotive electrical diagnostics

For EV work, the glove rating must be matched to the vehicle manufacturer's required PPE and electrical safety procedure.

Power Industry Applications

The extended cuff and electrical insulation characteristics make the AE3611 relevant to selected power-industry applications such as:

  • Electrical substations
  • Distribution equipment
  • Power cabinets
  • Switchgear
  • Electrical maintenance stations
  • Industrial power systems
  • Utility maintenance

Appropriate insulating PPE, arc-flash protection and other required equipment should be selected according to the specific task.

Chemical and Industrial Maintenance

Some distributor specifications describe the gloves as suitable for electrical, automotive, machinery and industrial applications.

However, chemical resistance should not be assumed solely from the rubber construction. Compatibility with specific chemicals must be verified before use.

Inspection Before Use

SATA's instructions specify that the gloves should be checked before every use. The inspection includes inflating the glove to check for air leakage and performing a visual inspection.

The user should check for:

  • Cuts
  • Tears
  • Punctures
  • Cracks
  • Surface damage
  • Deterioration
  • Air leakage
  • Other visible defects

A glove showing any unsafe condition should not be used and should be sent for appropriate testing or inspection.

Periodic Electrical Testing

Electrical insulating gloves require periodic inspection and electrical testing; they should not simply be stored and used indefinitely.

SATA's documentation states that Level 1, 2, 3 and 4 gloves should be tested at intervals no longer than six months, with a general three-month cycle noted in the instructions under GB/T 17622-2008.

The appropriate inspection and retest schedule should follow the applicable local regulations, workplace electrical safety program and manufacturer's instructions.

Proper Storage

Proper storage is important for preserving rubber insulation.

SATA recommends that the gloves be:

  • Stored in a dedicated container.
  • Protected from compression.
  • Kept unfolded rather than tightly folded.
  • Stored away from steam pipes and radiators.
  • Protected from direct sunlight.
  • Kept away from artificial light sources that may cause deterioration.
  • Protected from ozone sources.
  • Stored within the manufacturer's specified temperature conditions.

SATA's instructions specify an ambient storage temperature of approximately 10°C–21°C.

Protection During Use

The gloves should be protected from unnecessary exposure to:

  • Excessive heat
  • Direct light
  • Oil
  • Grease
  • Rosin
  • Petroleum solvents
  • Strong acids
  • Other potentially damaging chemicals

SATA recommends that when additional protective gloves are used over electrical insulating gloves, the protective gloves should be worn over the rubber insulating gloves, rather than underneath them.

Cleaning

If the gloves become dirty, SATA's instructions state that they can be cleaned using soap and water at a temperature not exceeding 65°C. They should then be thoroughly dried before storage.

Gloves that become wet during use or washing should be completely dried at a temperature not exceeding the specified limit.

Important PPE Limitation

The AE3611 is an electrical insulating glove, not a general-purpose mechanical glove.

It should not be relied upon as protection against:

  • Cutting
  • Puncture
  • Abrasion
  • Heavy mechanical impact
  • Arc-flash hazards
  • Every type of chemical exposure

Additional PPE may be required depending on the electrical work, including protective outer gloves, arc-rated clothing, face protection, safety footwear and other equipment.

Product Advantages

12KV verification voltage: Provides a high-voltage electrical insulation verification level.

7.5KV maximum operating voltage: Clearly specified by SATA for normal operating conditions.

Virgin rubber construction: Provides high electrical insulation performance.

360mm length: Provides extended wrist and lower-arm coverage.

Soft palm design: Supports flexibility and comfortable handling.

Tear resistance: Improves durability during normal handling.

Aging resistance: Helps maintain material performance when properly stored.

Strong toughness: Provides good resistance to normal deformation.

GB/T 17622-2008: Manufactured according to the stated electrical insulating glove standard.

Professional electrical PPE: Suitable for use in appropriate electrical maintenance and servicing procedures.

Recommended Applications

The SATA AE3611 is suitable for use as part of an appropriate electrical PPE system in:

  • Electrical maintenance
  • Power equipment servicing
  • Switchgear maintenance
  • Electrical panel work
  • Industrial electrical work
  • Utility maintenance
  • Distribution equipment
  • Electrical installation
  • Automotive electrical servicing
  • EV and hybrid vehicle maintenance
  • Machinery electrical maintenance
  • High-voltage equipment inspection

Product Highlights

The SATA AE3611 12KV Insulating Gloves for High-Voltage Work are professional electrical insulating gloves made from virgin rubber, featuring a 360mm extended design, soft palm construction, tear resistance, aging resistance and strong toughness. SATA specifies an AC 12,000V verification voltage with a 3-minute verification duration, while the current SATA product specification states an AC 7,500V maximum operating voltage. The gloves are manufactured to GB/T 17622-2008 and are intended for appropriate electrical maintenance and live-working procedures when used with the required PPE and safety controls.

Important: The 12KV figure is the verification/test voltage, not the normal operating voltage. The manufacturer's stated maximum operating voltage is AC 7,500V.



 Inquiry - SATA 12KV INSULATING GLOVES FOR HIGH-VOLTAGE - AE3611