The LEO LRP 15-90A/160 is a compact automatic hot-water circulation and pressure-boosting pump designed for domestic hot-water circulation, small heating systems, HVAC circulation and solar hot-water applications. It is particularly suited to small houses and space-constrained installations, where a compact, low-noise circulation pump is required. LEO's LRP range is designed for HVAC circulation, domestic hot-water circulation, central/district heating and hot-water pressure boosting applications.
The LRP 15-90A/160 has a 123 W motor, 220–230 V single-phase supply, maximum flow of 25 L/min, maximum head of 9 m, and a 160 mm installation length. Available Malaysian specifications also identify a 15 mm inlet/outlet, while the model's pump dimensions are listed with a G¾ connection in LEO documentation.
Product Specifications
| Specification | LEO LRP 15-90A/160 |
|---|---|
| Brand | LEO |
| Model | LRP 15-90A/160 |
| Product Type | Automatic Circulation Pump |
| Pump Application | Hot Water / Heating / HVAC Circulation |
| Motor Power | 123 W |
| Rated Output | 0.123 kW |
| Voltage | 220–230 V |
| Frequency | 50 Hz |
| Phase | Single Phase |
| Maximum Flow | 25 L/min |
| Maximum Flow | 1.5 m³/h |
| Maximum Head | 9 m |
| Maximum Working Pressure | 10 bar |
| Installation Length | 160 mm |
| Connection | G¾ |
| Nominal Pipe Connection | 15 mm |
| Operation Modes | Automatic / Continuous Circulation / Off |
| Maximum Liquid Temperature | Up to 60°C in LEO technical data |
| Impeller Material | Noryl |
| Shaft Material | 99% Alumina Ceramic |
| Bearing | 99% Alumina Ceramic |
| Motor Winding | Copper |
| Motor Insulation | Class H |
| Protection Class | IP42 |
| Pump Body | Anti-Rust Cast Iron |
| Installation | Inline / Pipe Mounted |
| Primary Application | Domestic Hot-Water Circulation |
The official LEO technical information lists 123 W power, 25 L/min maximum flow, 9 m maximum head, 160 mm installation length and G¾ connection for the LRP 15-90A/160.
Important Temperature Specification
There is a specification discrepancy among current listings that is worth noting for a product catalogue. LEO's technical page for this particular model lists a liquid-temperature range of 2°C–60°C, while some Malaysian dealer listings advertise the pump for hot-water service and state temperatures up to 110°C.
For a conservative website specification, I recommend listing 60°C as the verified LEO technical limit unless your supplied product datasheet specifically confirms the 110°C rating for your production version.
Product Overview
The LRP 15-90A/160 is designed differently from a conventional transfer pump. Its primary function is to maintain circulation and pressure within an existing water system, rather than pump large quantities of water from one tank to another.
Its compact dimensions make it particularly useful in residential installations where the available installation space is limited. A Malaysian supplier describes the LRP series as being designed for small housing and congested areas, while highlighting low noise, compact construction, durability and simple operation.
The 160 mm installation length is also important when using this pump as a replacement for an existing circulation pump. The available space between the pipe connections should be checked before installation.
Automatic Operation
The "A" designation is associated with the automatic version of the LRP 15-90A/160. One published technical listing identifies three operating selections:
- OFF
- Automatic operation
- Continuous circulation
This gives the user flexibility to operate the pump according to the requirements of the domestic water system.
Automatic operation is particularly useful in domestic hot-water applications where circulation or pressure assistance is required only when there is a demand.
123 W Motor
The pump is equipped with a 123 W single-phase motor, providing a compact solution for low- to medium-demand circulation requirements.
At 220–230 V, the pump can be used with conventional single-phase electrical supplies commonly available in residential and small commercial installations. Malaysian listings specify 220 V/50 Hz or 230 V/50 Hz, depending on the listing.
Maximum Flow – 25 L/min
The LRP 15-90A/160 has a published maximum flow of:
25 L/min ≈ 1.5 m³/h
This makes it suitable for relatively small circulation systems rather than large commercial heating networks.
The actual flow depends on:
- Pipe diameter
- Pipe length
- Static head
- System friction
- Valves and fittings
- Heat exchangers
- Radiators
- Operating mode
- Required outlet pressure
The 25 L/min figure represents the maximum flow capability and should not be interpreted as the flow available at the maximum 9 m head.
Maximum Head – 9 Metres
The LRP 15-90A/160 has a maximum head of approximately 9 m.
A 9 m water head corresponds to approximately 0.88 bar of water pressure under standard conditions. The actual pressure generated at a particular flow rate will be lower than the maximum shut-off head.
This head capability makes the pump suitable for:
- Small multi-storey domestic circulation
- Hot-water circulation loops
- Small heating circuits
- Solar water circulation
- Small HVAC circulation
- Domestic pressure assistance
Compact 160 mm Design
The 160 mm installation length is one of the key characteristics of the LRP 15-90A/160.
The LEO dimensional information gives approximately:
- A: 129 mm
- B: 160 mm
- C: 120 mm
- Connection: G¾
This compact configuration makes the pump useful for replacement installations and confined mechanical spaces.
G¾ / 15 mm Connection
The model is associated with a G¾ connection, while Malaysian listings specify the inlet/outlet as 15 mm.
Before installation, the existing pipe connection should be checked carefully because nominal pipe size, thread size and actual pipe outside diameter are not necessarily interchangeable specifications.
Pump Construction
The LRP 15-90A/160 incorporates several materials intended for long-term circulation-pump operation.
Anti-Rust Cast-Iron Pump Body
The pump body is specified as anti-rust cast iron, providing a robust housing for domestic circulation applications.
Noryl Impeller
The impeller is made from Noryl. LEO specifies Noryl for the LRP series and lists heat resistance up to approximately 150°C for the impeller material. The allowable pumped-liquid temperature is nevertheless governed by the complete pump specification.
99% Alumina Ceramic Shaft
The shaft uses 99% alumina ceramic, which is well suited to wet-rotor circulation-pump construction.
99% Alumina Ceramic Bearing
The pump also uses a 99% alumina ceramic bearing, designed for reliable operation in the circulating fluid.
Copper Motor Winding
The motor uses copper winding, supporting efficient electrical and thermal performance.
Low-Noise Operation
The LRP 15-90A/160 is designed for low-noise operation, which is particularly important for residential installations.
Because circulation pumps are frequently installed close to living spaces, bedrooms, bathrooms or domestic hot-water systems, reducing mechanical and hydraulic noise is a useful feature.
Correct installation is still important: air trapped inside the system, excessive flow velocity, cavitation or incorrectly selected pipework can produce noise even when the pump itself is designed for quiet operation.
Recommended Applications
The LEO LRP 15-90A/160 is suitable for:
- Domestic hot-water circulation
- Household water circulation
- Small heating systems
- Radiator circulation
- Small HVAC systems
- Solar hot-water circulation
- Small underfloor-heating systems
- Hot-water pressure boosting
- Small closed-loop circulation systems
- Residential water circulation
- Small commercial hot-water systems
LEO lists the LRP family for HVAC circulation, domestic hot-water circulation, central and district heating, solar-powered hot-water systems and industrial auxiliary hot- and cold-water circulation.
Suitable Fluid
The pump is primarily intended for clean water and compatible water-like liquids.
Suitable applications include:
- Clean domestic water
- Heating water
- Hot-water circulation
- Solar-heating circulation
- Compatible treated water
It should not be used for sewage, abrasive slurry, heavily contaminated water or liquids containing significant quantities of suspended solids unless specifically approved by LEO.
Installation Recommendations
For proper operation:
- Install the pump in the correct flow direction.
- Confirm the 160 mm installation length before installation.
- Verify the G¾/15 mm connection compatibility.
- Flush the pipework before installing the pump.
- Remove air from the circulation system.
- Ensure the system contains sufficient water.
- Select the appropriate operating mode.
- Check all connections for leakage after commissioning.
- Avoid operating the pump without the required circulating liquid.
- Follow LEO's installation instructions for correct pump orientation.
For wet-rotor circulation pumps, the circulating fluid provides lubrication and cooling for the internal rotor/bearing arrangement, so dry running should be avoided.
Advantages of LEO LRP 15-90A/160
- Compact 160 mm installation length for space-constrained installations.
- 123 W motor for efficient small-system circulation.
- 25 L/min maximum flow for domestic applications.
- 9 m maximum head for useful circulation pressure.
- Automatic operating mode for convenient water circulation.
- Continuous circulation mode when required.
- Low-noise operation for residential installations.
- 99% alumina ceramic shaft for durable wet-rotor operation.
- 99% alumina ceramic bearing for reliable circulation.
- Noryl impeller with high-temperature material resistance.
- Copper motor winding.
- Class H insulation.
- IP42 protection.
- Anti-rust cast-iron pump body.
- 220–230 V single-phase supply.
- Suitable for domestic hot-water, heating, HVAC and solar-water circulation.
LRP 15-90A/160 Performance Summary
| Parameter | Specification |
|---|---|
| Motor Power | 123 W |
| Maximum Flow | 25 L/min |
| Maximum Flow | 1.5 m³/h |
| Maximum Head | 9 m |
| Installation Length | 160 mm |
| Connection | G¾ |
| Pipe Connection | 15 mm |
| Voltage | 220–230 V |
| Frequency | 50 Hz |
| Maximum Working Pressure | 10 bar |
| Liquid Temperature | 2°C–60°C* |
| Motor Insulation | Class H |
| Protection | IP42 |
| Shaft | 99% Alumina Ceramic |
| Bearing | 99% Alumina Ceramic |
| Impeller | Noryl |
| Winding | Copper |
*LEO's technical data lists 2°C–60°C for this model; some Malaysian commercial listings state a higher temperature rating, so the exact rating should be confirmed from the supplied pump nameplate/datasheet before specifying 110°C in a catalogue.
Website Product Description
LEO LRP 15-90A/160 123W Automatic Hot Water Circulation Pump is a compact and reliable circulation pump designed for domestic hot-water circulation, small heating systems, HVAC applications and solar-water circulation. Powered by a 123 W single-phase motor, the pump delivers up to 25 L/min flow and develops a maximum head of 9 metres, providing useful circulation performance for residential and small commercial systems.
Featuring a compact 160 mm installation length, the LRP 15-90A/160 is particularly suitable for small houses, congested mechanical areas and replacement installations where space is limited. Its automatic configuration provides convenient operation, while the pump can also be operated in continuous-circulation mode where required.
The pump incorporates an anti-rust cast-iron body, Noryl impeller, 99% alumina ceramic shaft, 99% alumina ceramic bearing and copper motor winding. It is designed for quiet and durable operation and is suitable for clean-water circulation applications.
Typical applications include domestic hot-water circulation, household water systems, small heating systems, HVAC circulation, solar hot-water systems, radiator circulation and other small closed-loop water-circulation applications. LEO identifies the LRP range for heating, HVAC, domestic hot-water and solar-related circulation duties.