The LEO LPP 80-14-3/2 is a single-stage, close-coupled vertical in-line centrifugal circulation pump designed for high-volume water circulation in HVAC, heating, cooling, water-supply and industrial systems. The LPP series is intended for hot-water circulation, boiler systems, air-conditioning cooling-water circulation, waterworks transfer, main-pipe pressure boosting, water treatment and industrial auxiliary applications.

For the exact LPP80-14-3/2, LEO's published technical data specifies a 3 kW motor, 2,900 rpm, 55 m³/h nominal flow, 14 m nominal head, 75 m³/h maximum flow, 17 m maximum head, and approximately 3 m NPSH required.

Product Specifications

Specification LEO LPP 80-14-3/2
Brand LEO
Model LPP 80-14-3/2
Product Type Vertical In-Line Circulation Pump
Pump Type Single-Stage Centrifugal
Design Close-Coupled
Motor Power 3 kW
Approx. Motor Power 4 HP
Motor Configuration 2-Pole
Rated Speed 2,900 rpm
Rated Flow 55 m³/h
Rated Head 14 m
Maximum Flow 75 m³/h
Maximum Head 17 m
NPSH Required Approx. 3 m
Nominal Connection DN80 / 3"
Connection Type Flanged
Electrical Supply 3-Phase
Typical Voltage 380–415 V
Frequency 50 Hz
Maximum Liquid Temperature Up to 90°C*
Maximum Operating Pressure Up to 16 bar*
Motor Insulation Class F*
Motor Protection IP55*
Pump Arrangement Vertical In-Line
Pump Stages Single Stage
Main Applications HVAC / Heating / Cooling / Water Supply / Industrial

*These are LPP-series specifications commonly associated with this range; verify the exact nameplate/datasheet for the supplied production configuration before installation.

The model-specific hydraulic figures—3 kW, 2,900 rpm, 55 m³/h nominal flow, 14 m nominal head, 75 m³/h maximum flow, 17 m maximum head and 3 m NPSH—are confirmed by the LPP80 technical table.

Model Code Explanation

The model designation LPP 80-14-3/2 generally identifies:

  • LPP – LEO vertical in-line pump series
  • 80 – nominal DN80 connection size
  • 14 – nominal head of approximately 14 m
  • 3 – 3 kW motor power
  • /2 – 2-pole motor configuration

The LEO LPP80 model table confirms this model as the 3 kW / 2,900 rpm / 55 m³/h / 14 m head configuration.

Rated Hydraulic Performance

The nominal operating point is:

Rated Flow: 55 m³/h
Rated Head: 14 m
Motor Power: 3 kW
Speed: 2,900 rpm

A flow of 55 m³/h is equivalent to approximately:

917 L/min

The published maximum performance is:

Maximum Flow: 75 m³/h
Maximum Head: 17 m

The maximum flow and maximum head are separate points on the pump curve and should not be interpreted as the pump delivering 75 m³/h at 17 m head simultaneously. Actual performance depends on the system curve and hydraulic resistance.

Hydraulic Performance Summary

Parameter Value
Rated Flow 55 m³/h
Rated Flow ≈917 L/min
Rated Head 14 m
Maximum Flow 75 m³/h
Maximum Flow ≈1,250 L/min
Maximum Head 17 m
Motor Power 3 kW
Approx. Motor Rating 4 HP
Speed 2,900 rpm
NPSH Required ≈3 m

This makes the LPP 80-14-3/2 particularly suitable where large water volumes must be circulated at a relatively moderate head.

3 kW Motor

The LPP 80-14-3/2 is fitted with a 3 kW, two-pole motor, operating at approximately 2,900 rpm at 50 Hz.

The motor provides the mechanical power required to achieve the model's nominal duty of 55 m³/h at 14 m head.

For a typical Malaysian three-phase installation, the expected supply configuration is 380–415 V, 50 Hz, subject to the actual pump nameplate.

Appropriate electrical protection should be provided, including:

  • Motor overload protection
  • Short-circuit protection
  • Electrical isolator
  • Proper earthing
  • Suitable motor starter or control system
  • Correct phase rotation

DN80 / 3-Inch Connection

The "80" in LPP 80 indicates the nominal DN80 connection size, approximately equivalent to a 3-inch nominal pipe connection.

This larger connection is appropriate for high-flow circulation systems where the required flow is considerably greater than that of the LPP50 models.

Typical DN80 applications include:

  • Large HVAC circulation loops
  • Chilled-water systems
  • Cooling-water systems
  • Central heating systems
  • Boiler circulation
  • Commercial building plant rooms
  • Industrial process-water circulation

For replacement applications, the existing pipework should be checked for:

  • DN80 compatibility
  • Flange standard
  • Flange dimensions
  • Bolt-hole pattern
  • Face-to-face dimension
  • Pipe alignment
  • Motor clearance

Vertical In-Line Construction

The LPP 80-14-3/2 uses a vertical in-line configuration, allowing the pump to be installed directly within the pipeline.

The suction and discharge ports are positioned along the same piping axis, making the pump particularly useful where a conventional horizontal pump arrangement would require more floor space.

Benefits include:

  • Compact footprint
  • Direct in-line installation
  • Efficient use of mechanical-room space
  • Straightforward pipe routing
  • Suitable for HVAC plant rooms
  • Suitable for commercial and industrial circulation systems

LEO identifies the LPP as a vertical in-line pump and specifically lists HVAC, air-conditioning, water-supply, industrial and fire-fighting applications.

Single-Stage Centrifugal Design

The LPP 80-14-3/2 is a single-stage centrifugal pump.

The rotating impeller transfers mechanical energy from the motor into the water, generating the required flow and pressure. The single-stage configuration is appropriate for applications requiring high flow with moderate system head.

At 55 m³/h rated flow and 14 m rated head, this model is more oriented toward high-volume circulation than high-pressure water boosting.

High-Flow Capability

One of the main characteristics of the LPP 80-14-3/2 is its relatively high flow capacity.

The published figures are:

Rated: 55 m³/h
Maximum: 75 m³/h

Converted to litres per minute:

  • 55 m³/h ≈ 917 L/min
  • 75 m³/h ≈ 1,250 L/min

This makes the pump suitable for large-volume circulation in systems such as chilled-water loops, cooling-water circuits and commercial HVAC installations.

Maximum Head – 17 m

The published maximum head is approximately 17 m, compared with the nominal operating head of 14 m.

A 17 m water column corresponds to approximately 1.67 bar of water pressure under standard conditions.

The maximum head is associated with the low-flow region of the pump curve. It should not be treated as the normal operating point.

NPSH Requirement

The LPP 80-14-3/2 has a published NPSH requirement of approximately 3 m.

This is an important consideration for high-flow applications.

Adequate suction conditions are necessary to prevent cavitation, particularly when:

  • Pumping hot water
  • Suction pipework is long
  • Suction piping is undersized
  • There are excessive suction-side fittings
  • The pump is installed above the liquid source
  • System inlet pressure is low

Cavitation can cause vibration, noise, loss of performance and premature impeller or mechanical-seal damage.

Recommended Applications

LEO's LPP series is designed for a broad range of circulation and water-transfer duties, including:

  • HVAC hot-water circulation
  • Central heating
  • Boiler circulation
  • Boiler mixing systems
  • Temperature-mixing systems
  • Air-conditioning cooling-water circulation
  • Chilled-water circulation
  • Cooling-water circulation
  • Waterworks filtration
  • Water transfer
  • Main-pipeline pressure boosting
  • Water treatment
  • Boiler feed applications
  • Industrial washing and cleaning
  • Industrial auxiliary systems
  • Fire-fighting systems

The LPP 80-14-3/2 is especially appropriate for applications where a large quantity of water must be circulated through a relatively low-to-moderate resistance system.

Suitable Fluids

The pump is primarily intended for clean water and liquids with physical and chemical characteristics similar to water.

Suitable fluids may include:

  • Clean water
  • Heating water
  • Chilled water
  • Cooling water
  • Treated process water
  • Boiler circulation water
  • Compatible water-based fluids

For abrasive, corrosive or solids-containing liquids, the pump's materials and mechanical seal must be confirmed for the specific fluid.

Temperature Applications

The LPP series is designed for circulation applications involving both heating and cooling water. LEO specifically lists hot-water HVAC circulation, boiler applications and cooling-water circulation among the intended uses.

Typical applications include:

Heating:
Central heating, boiler circulation, hot-water circulation and heat-transfer systems.

Cooling:
Chilled-water circulation, air-conditioning systems and cooling-water loops.

For actual maximum liquid temperature, pressure and seal compatibility, the exact pump nameplate and supplied technical documentation should be followed.

Motor Protection

The LPP series is generally configured with a Class F insulation system and IP55 motor enclosure.

IP55 protection provides protection against harmful dust deposits and water jets from any direction, making the motor appropriate for many commercial plant-room and industrial environments.

For long service life, the motor should nevertheless be protected from prolonged water exposure, flooding and excessive ambient temperatures.

Installation Considerations

The LPP 80-14-3/2 should be installed by qualified personnel.

Important installation requirements include:

  1. Confirm the required flow and head.
  2. Verify DN80 flange compatibility.
  3. Confirm the actual flange standard.
  4. Check pump face-to-face dimensions.
  5. Ensure the pipeline is properly supported.
  6. Avoid imposing excessive pipe loads on the pump.
  7. Install according to the indicated flow direction.
  8. Fill the system before starting the pump.
  9. Vent trapped air.
  10. Confirm sufficient suction pressure.
  11. Verify three-phase motor rotation.
  12. Check operating current during commissioning.
  13. Ensure sufficient motor ventilation.
  14. Prevent dry running.
  15. Inspect all flange joints for leakage.

Because this is a high-flow DN80 pump, suction and discharge pipework sizing is particularly important. Excessively restrictive suction pipework can significantly reduce the available NPSH margin.

Pump Selection

The LPP 80-14-3/2 should be selected according to the system's actual duty point.

The key selection parameters are:

Required Flow (Q)
Required Head (H)
Fluid Temperature
System Operating Pressure
Fluid Characteristics
Electrical Supply

A system requiring approximately 55 m³/h at 14 m head is closely aligned with the model's published nominal duty.

If the system requires substantially more head, a different LPP80 model may be more appropriate. LEO's LPP80 range includes models with rated heads from approximately 8.5 m through 80 m, depending on motor and configuration.

Comparison With LPP80 Models

Model Motor Rated Flow Rated Head Max Flow Max Head
LPP80-8.5-1.5/2 1.5 kW 45 m³/h 8.5 m 65 m³/h 10.5 m
LPP80-10.5-2.2/2 2.2 kW 52 m³/h 10.5 m 70 m³/h 14 m
LPP80-14-3/2 3 kW 55 m³/h 14 m 75 m³/h 17 m
LPP80-17-4/2 4 kW 64 m³/h 17 m 79 m³/h 21 m
LPP80-20-5.5/2Δ 5.5 kW 70 m³/h 20 m 90 m³/h 25 m

The figures above are from the published LEO LPP80 technical table.

The LPP80-14-3/2 therefore occupies a useful position in the range: it provides high flow without the higher motor power required by the 4 kW and 5.5 kW models.

Key Advantages

  1. 3 kW motor for commercial and industrial circulation.
  2. Approximately 4 HP motor rating.
  3. 55 m³/h rated flow.
  4. 14 m rated head.
  5. 75 m³/h maximum flow.
  6. 17 m maximum head.
  7. Approximately 917 L/min rated capacity.
  8. Approximately 1,250 L/min maximum capacity.
  9. 2,900 rpm two-pole motor.
  10. DN80 / 3-inch connection.
  11. Vertical in-line configuration.
  12. Single-stage centrifugal design.
  13. Close-coupled construction.
  14. Approximately 3 m NPSH requirement.
  15. Suitable for heating and cooling applications.
  16. Suitable for HVAC and commercial building systems.
  17. Suitable for industrial water circulation.
  18. Designed for direct in-line installation.
  19. LEO LPP series support for HVAC, water supply, industrial and fire-fighting applications.

Detailed Performance Summary

Parameter LEO LPP 80-14-3/2
Motor Power 3 kW
Approx. Horsepower 4 HP
Motor Type 2-Pole / 3-Phase
Speed 2,900 rpm
Rated Flow 55 m³/h
Rated Flow ≈917 L/min
Rated Head 14 m
Maximum Flow 75 m³/h
Maximum Flow ≈1,250 L/min
Maximum Head 17 m
NPSH Required ≈3 m
Connection DN80 / 3"
Connection Type Flanged
Pump Configuration Vertical In-Line
Pump Stages Single Stage
Application HVAC / Heating / Cooling / Industrial

The hydraulic performance figures are confirmed by the published LEO LPP80 model table.

Website Product Description

LEO LPP 80-14-3/2 Vertical In-Line Circulation Pump 3kW is a high-flow single-stage centrifugal pump designed for commercial HVAC, heating, cooling, water-supply and industrial circulation systems. Equipped with a 3 kW three-phase, 2-pole motor operating at approximately 2,900 rpm, the pump provides a rated flow of 55 m³/h at 14 m head, with maximum hydraulic performance of approximately 75 m³/h flow and 17 m head.

Featuring a DN80 / 3-inch in-line connection, the pump is designed for integration into larger water-circulation pipelines. Its vertical in-line construction provides a compact installation arrangement for mechanical rooms, HVAC plants, central heating systems and industrial facilities. LEO specifies the LPP series for hot-water circulation, boiler systems, cooling-water circulation, waterworks transfer, pressure boosting, water treatment and industrial auxiliary applications.

With its 3 kW motor, 55 m³/h rated flow, 14 m rated head and approximately 3 m NPSH requirement, the LEO LPP 80-14-3/2 is particularly suitable for high-volume water circulation where moderate system head is required. It is an appropriate choice for HVAC chilled-water systems, cooling-water circuits, central heating, boiler circulation, heat-transfer systems, water-treatment installations and industrial process-water circulation.

SEO Product Title

LEO LPP 80-14-3/2 Vertical In-Line Circulation Pump 3kW 4HP 3-Phase DN80

SEO Meta Description

LEO LPP 80-14-3/2 vertical in-line circulation pump with 3kW motor, 55m³/h rated flow and 14m head. DN80 pump for HVAC, heating, cooling and industrial water circulation.



 Inquiry - LEO CIRCULATION PUMPS - LPP 80-14-3/2