B116, C15 Jalan Haji Ahmad, Perkampungan Seri Setali, 25300 Kuantan, Pahang, Malaysia.

+6019-323 7617

kstoolsdepot@gmail.com


Share:


LEO CIRCULATION PUMPS - LPP 40-13-0.75/2



The LEO LPP 40-13-0.75/2 is a single-stage, close-coupled vertical in-line centrifugal pump designed primarily for circulation and water-transfer duties in HVAC, heating, air-conditioning, water-supply and industrial systems. Unlike the smaller LRP circulator range, the LPP is a higher-capacity vertical in-line pump with a standard three-phase motor and flanged pipe connections. LEO specifies the LPP series for hot-water circulation, cooling-water circulation, waterworks transfer, pressure boosting, boiler feeding, water treatment and industrial auxiliary systems.

For the LPP 40-13-0.75/2, published technical data gives a rated flow of 10 m³/h, rated head of 13 m, rated speed of 2,900 rpm, and 0.75 kW motor power. The available LEO technical table also lists a maximum flow of approximately 15.5 m³/h, maximum head of approximately 16.5 m, and NPSHc of approximately 2 m.

Product Specifications

Specification LEO LPP 40-13-0.75/2
Brand LEO
Model LPP 40-13-0.75/2
Product Type Vertical In-Line Centrifugal Pump
Pump Design Single-Stage, Close-Coupled
Pump Configuration In-Line
Motor Power 0.75 kW
Motor Power Approx. 1 HP
Rated Speed 2,900 rpm
Rated Flow 10 m³/h
Rated Head 13 m
Maximum Flow 15.5 m³/h
Maximum Head 16.5 m
NPSH Required Approx. 2 m
Motor Supply 3-Phase
Typical Voltage 380–415 V
Frequency 50 Hz
Nominal Connection DN40
Pump Connection Flanged
Installation Vertical In-Line
Pump Stages Single Stage
Pump Coupling Close Coupled
Maximum Liquid Temperature 90°C
Maximum Operating Pressure 16 bar
Ambient Temperature Up to 40°C
Insulation Class F
Protection Class IP55
Motor Efficiency IE2 Standard
IE3 Motor Available on request
Application Water / Heating / HVAC / Cooling
Manufacturer LEO

The published LEO LPP40 data specifies 0.75 kW, 2,900 rpm, 10 m³/h rated flow, 13 m rated head, 15.5 m³/h maximum flow and 16.5 m maximum head for this exact model.

Model Code Explanation

The model designation LPP 40-13-0.75/2 can be understood generally as follows:

  • LPP – LEO vertical in-line pump series
  • 40 – nominal pump/pipe connection size, DN40
  • 13 – rated head of approximately 13 m
  • 0.75 – 0.75 kW motor power
  • /2 – 2-pole motor configuration, corresponding to approximately 2,900 rpm at 50 Hz

The exact nomenclature should be checked against the nameplate for contractual ordering purposes, but the published LEO model table confirms the principal parameters above.

Product Overview

The LPP 40-13-0.75/2 is designed for direct in-line installation into a piping system. Its suction and discharge ports are positioned in-line, allowing the pump to be installed within the existing pipeline without the conventional horizontal centrifugal-pump arrangement.

This configuration is particularly useful for mechanical rooms and HVAC systems where space efficiency, straightforward pipe routing and compact installation are important.

LEO describes the LPP series as a single-stage, close-coupled in-line centrifugal pump incorporating a mechanical shaft seal, hydraulically balanced impeller and anti-corrosion surface treatment.

Rated Hydraulic Performance

The LPP 40-13-0.75/2 has a rated duty point of:

Flow: 10 m³/h
Head: 13 m
Motor: 0.75 kW
Speed: 2,900 rpm

The maximum published performance is approximately:

Maximum flow: 15.5 m³/h
Maximum head: 16.5 m

 

The rated point and maximum point should not be confused. The pump does not deliver 15.5 m³/h at 16.5 m head. These are separate limits on the pump performance curve.

For system selection, the actual duty point should be determined from the required flow and total dynamic head.

Hydraulic Performance

At the rated duty point:

10 m³/h = approximately 166.7 L/min

Therefore, the LPP 40-13-0.75/2 is capable of circulating approximately 167 L/min at its rated 13 m head duty point.

The actual operating point will depend on the resistance of the connected pipe system, including:

  • Pipe length
  • Pipe diameter
  • Elbows
  • Valves
  • Filters
  • Heat exchangers
  • Cooling coils
  • Boilers
  • Radiators
  • Other system components

For proper selection, the system curve should intersect the LPP pump curve at or near the required duty point.

0.75 kW Motor

The pump is equipped with a 0.75 kW, 2-pole motor operating at approximately 2,900 rpm.

The LPP series uses a closed motor construction, with Class F insulation and IP55 protection. LEO specifies IE2 efficiency as standard, with IE3 available on request.

The motor configuration makes the LPP 40-13-0.75/2 suitable for commercial and industrial installations where a conventional three-phase electrical supply is available.

Vertical In-Line Construction

One of the principal advantages of the LPP design is its vertical in-line configuration.

The pump is installed directly into the pipeline, allowing:

  • Compact mechanical-room installation
  • Reduced floor-space requirements
  • Straightforward suction/discharge pipe routing
  • Convenient integration into HVAC systems
  • Easier replacement of compatible in-line pumps
  • Reduced footprint compared with some conventional horizontal pump arrangements

LEO specifically describes the LPP series as compact and easy to maintain.

Single-Stage Close-Coupled Design

The LPP 40-13-0.75/2 uses a single-stage centrifugal hydraulic design with the pump and motor arranged as a close-coupled assembly.

This construction eliminates the need for a separate long coupling arrangement between the pump and motor and provides a relatively compact package.

LEO describes the LPP series as having a mechanical shaft seal and hydraulically balanced impeller, together with anti-corrosion surface treatment.

Flanged DN40 Connections

The LPP 40 model is designed around a DN40 pipe connection and uses flanged connections.

This makes the pump particularly suitable for larger circulation systems compared with small threaded domestic circulators.

For replacement applications, the existing installation should be checked for:

  • DN40 pipe size
  • Flange standard
  • Flange dimensions
  • Bolt-hole arrangement
  • Pump face-to-face dimensions
  • Available vertical clearance
  • Motor clearance

LEO states that the LPP series uses EN 1092 and DIN 2576 flange standards in its published specifications.

Temperature Capability

The LPP series is designed for water circulation applications involving elevated liquid temperatures. LEO's published operating conditions specify a liquid-temperature range of approximately 0°C to +90°C.

This makes the LPP 40-13-0.75/2 suitable for many:

  • Heating-water systems
  • HVAC systems
  • Cooling-water systems
  • Boiler circulation systems
  • Industrial hot-water systems

The actual allowable temperature should always be checked against the pump nameplate and mechanical-seal specification for the particular production version.

Maximum Operating Pressure

LEO specifies a maximum operating pressure of approximately 16 bar for the LPP series.

This makes the pump suitable for pressurised commercial and industrial circulation systems, subject to correct system design and the applicable temperature/pressure combination.

NPSH Requirement

The published technical table gives an NPSH required/cavitation allowance of approximately 2 m for the LPP 40-13-0.75/2.

NPSH is important when pumping hot water or when the pump is installed with restricted suction conditions. Adequate suction pressure must be maintained to prevent cavitation.

Cavitation can produce:

  • Noise
  • Vibration
  • Reduced hydraulic performance
  • Impeller damage
  • Premature bearing/seal wear

For hot-water applications, particular attention should be paid to inlet pressure and water temperature.

Recommended Applications

The LEO LPP 40-13-0.75/2 is suitable for:

  • HVAC water circulation
  • Central heating systems
  • Hot-water circulation
  • Boiler circulation
  • Cooling-water circulation
  • Air-conditioning systems
  • Chilled-water circulation
  • Heat-exchanger circulation
  • Water-treatment systems
  • Waterworks transfer
  • Main-pipe pressure boosting
  • Industrial auxiliary circulation
  • Washing and cleaning systems
  • Industrial process-water circulation
  • General clean-water pumping

LEO's official LPP documentation lists HVAC hot-water circulation, boiler mixing and temperature mixing, air-conditioning cooling-water circulation, waterworks filtration and transfer, main-pipe pressure boosting, boiler feeding, cooling-water circulation, water treatment and industrial auxiliary systems among the applications.

Suitable Fluids

The LPP 40-13-0.75/2 is primarily designed for clean water and compatible water-based liquids.

Typical fluids include:

  • Clean water
  • Heating water
  • Cooling water
  • Chilled water
  • Boiler circulation water
  • Treated industrial water
  • Compatible water-based fluids

LEO's LPP series is designed for water-circulation applications and specifies liquid temperatures from 0°C to 90°C.

It should not be selected for highly abrasive slurry, sewage or chemically aggressive liquids unless the pump materials and mechanical seal have been specifically confirmed for that medium.

Motor and Protection

The LPP 40-13-0.75/2 uses:

Insulation Class: F
Protection: IP55
Efficiency: IE2 standard
IE3: Available on request
Motor: Closed construction
Speed: 2,900 rpm

IP55 protection provides substantially greater enclosure protection than the IP44 ratings typically associated with smaller domestic circulator pumps, making the LPP better suited to commercial and industrial mechanical-room environments.

Advantages of LEO LPP 40-13-0.75/2

  1. Vertical in-line configuration saves installation space.
  2. 0.75 kW motor provides useful capacity for commercial circulation.
  3. 10 m³/h rated flow for medium-duty water circulation.
  4. 13 m rated head at the rated operating point.
  5. 16.5 m maximum head according to published LEO data.
  6. 15.5 m³/h maximum flow according to the published pump table.
  7. 2,900 rpm two-pole motor provides compact high-speed operation.
  8. DN40 flanged connections for larger pipework.
  9. Single-stage close-coupled construction simplifies the pump package.
  10. Mechanical shaft seal for reliable fluid containment.
  11. Hydraulically balanced impeller for stable pump operation.
  12. Class F insulation for the motor.
  13. IP55 protection for improved environmental protection.
  14. IE2 motor efficiency as standard, with IE3 available.
  15. Up to 90°C liquid temperature for suitable heating applications.
  16. 16 bar maximum operating pressure for suitable systems.
  17. Suitable for HVAC, heating, cooling, water supply and industrial applications.

Installation Considerations

The LPP 40-13-0.75/2 should be installed by appropriately qualified personnel.

Important installation considerations include:

  • Confirm the pump flow direction.
  • Match the DN40 flanges correctly.
  • Use appropriate flange gaskets.
  • Ensure pipework is adequately supported.
  • Do not allow the pump to carry excessive pipe loads.
  • Ensure sufficient straight pipe and suction conditions where required.
  • Fill and vent the system before commissioning.
  • Confirm that the pump is fully flooded before operation.
  • Check motor rotation for the three-phase supply.
  • Verify operating current against the motor nameplate.
  • Ensure adequate ventilation around the motor.
  • Protect the pump from dry running.

Because the pump is a vertical in-line centrifugal pump, correct installation orientation and pipe support are especially important.

LPP 40-13-0.75/2 vs Small LRP Circulation Pumps

The LPP 40-13-0.75/2 is fundamentally different from the smaller LRP circulators listed previously.

Feature LEO LPP 40-13-0.75/2
Pump Type Vertical In-Line Centrifugal
Motor 0.75 kW
Speed 2,900 rpm
Rated Flow 10 m³/h
Rated Head 13 m
Max Flow 15.5 m³/h
Max Head 16.5 m
Connection DN40 Flanged
Motor Supply 3-Phase
Application Commercial / Industrial
Primary Duty HVAC / Heating / Cooling / Water Supply

The LPP therefore provides a substantially different duty range from compact domestic circulators such as the LRP 15-90A/160.

Website Product Description

LEO LPP 40-13-0.75/2 Vertical In-Line Centrifugal Pump 0.75kW is a robust single-stage, close-coupled pump designed for HVAC, heating, air-conditioning, cooling-water circulation, water supply and industrial applications. Equipped with a 0.75 kW two-pole motor operating at approximately 2,900 rpm, the pump has a rated capacity of 10 m³/h at 13 m head, with a maximum flow of approximately 15.5 m³/h and maximum head of 16.5 m.

The vertical in-line design allows the pump to be installed directly within the pipeline, providing a compact solution for mechanical rooms and commercial plant rooms. The DN40 flanged construction is suitable for larger circulation pipework, while the single-stage close-coupled design provides a compact and serviceable pump package. LEO specifies a mechanical shaft seal, hydraulically balanced impeller and anti-corrosion surface treatment for the LPP series.

The LPP 40-13-0.75/2 is suitable for hot-water circulation, central heating, HVAC systems, air-conditioning cooling-water circulation, boiler circulation, heat exchangers, water treatment, waterworks transfer, main-pipe pressure boosting and industrial auxiliary systems. The pump is specified for liquid temperatures up to approximately 90°C, maximum operating pressure of 16 bar, Class F motor insulation and IP55 motor protection.

SEO Product Title

LEO LPP 40-13-0.75/2 Vertical In-Line Centrifugal Pump 0.75kW 3-Phase DN40

SEO Meta Description

LEO LPP 40-13-0.75/2 vertical in-line centrifugal pump with 0.75kW motor, 10m³/h rated flow and 13m rated head. Ideal for HVAC, heating, cooling and industrial circulation.



 Inquiry - LEO CIRCULATION PUMPS - LPP 40-13-0.75/2