The LEO LPP 50-12-1.1/2 is a single-stage, close-coupled vertical in-line centrifugal circulation pump designed for medium-duty and commercial water-circulation applications. It is suitable for HVAC, central heating, air-conditioning cooling-water circulation, boiler systems, water supply, pressure boosting, water treatment and industrial auxiliary circulation. LEO's official LPP range is specifically designed for hot-water circulation, cooling-water circulation, waterworks transfer, pressure boosting and industrial applications.
For this model, the published LEO technical data specifies a 1.1 kW motor, 2,900 rpm, 20 m³/h rated flow, 12 m rated head, maximum flow of 26 m³/h, and maximum head of 15 m. The model has a DN50 flanged connection and 340 mm installation length.
Product Specifications
| Specification | LEO LPP 50-12-1.1/2 |
|---|---|
| Brand | LEO |
| Model | LPP 50-12-1.1/2 |
| Product Type | Vertical In-Line Circulation Pump |
| Pump Type | Single-Stage Centrifugal |
| Design | Close-Coupled |
| Motor Power | 1.1 kW |
| Approx. Motor Power | 1.5 HP |
| Motor Poles | 2 Pole |
| Rated Speed | 2,900 rpm |
| Rated Flow | 20 m³/h |
| Rated Head | 12 m |
| Maximum Flow | 26 m³/h |
| Maximum Head | 15 m |
| NPSH Required | Approx. 2 m |
| Connection Size | DN50 |
| Connection Type | Flanged |
| Installation Length | 340 mm |
| Power Supply | 3-Phase |
| Typical Supply | 380–415 V |
| Frequency | 50 Hz |
| Maximum Liquid Temperature | 90°C |
| Maximum Working Pressure | 16 bar |
| Maximum Ambient Temperature | 40°C |
| Motor Insulation | Class F |
| Motor Protection | IP55 |
| Motor Efficiency | IE2 |
| Higher Efficiency Option | IE3 available on request |
| Pump Arrangement | Vertical In-Line |
| Suitable Fluid | Clean Water / Water-Like Fluids |
The model-specific LPP50 technical table confirms 1.1 kW, 2,900 rpm, 20 m³/h nominal flow, 12 m nominal head, 26 m³/h maximum flow and 15 m maximum head.
Product Overview
The LPP 50-12-1.1/2 is designed for applications where a conventional compact domestic circulator is insufficient and a higher-capacity, flanged in-line pump is required.
Its vertical in-line arrangement allows the pump to be incorporated directly into the piping system. This is particularly useful in mechanical rooms, HVAC plant rooms, heating systems and industrial installations, where floor space and straight-through pipe routing are important.
The close-coupled construction integrates the motor and pump into a compact assembly, while the single-stage centrifugal hydraulic design provides the flow and head required for medium-capacity circulation. LEO identifies the LPP range for HVAC circulation, air-conditioning cooling-water circulation, waterworks transfer, pressure boosting, boiler feeding, water treatment and industrial auxiliary applications.
Rated Hydraulic Performance
The LEO LPP 50-12-1.1/2 has a rated operating point of:
Flow: 20 m³/h
Head: 12 m
Motor: 1.1 kW
Speed: 2,900 rpm
This corresponds to approximately:
20 m³/h = 333 L/min
The published maximum performance is:
Maximum flow: 26 m³/h
Maximum head: 15 m
The rated flow and rated head should be regarded as the model's nominal duty point, whereas the maximum flow and maximum head represent separate limits on the hydraulic performance curve. The pump will not provide 26 m³/h at 15 m head simultaneously.
For system selection, the required flow and total dynamic head should be matched against the actual pump curve.
1.1 kW Motor
The LPP 50-12-1.1/2 is equipped with a 1.1 kW two-pole motor operating at approximately 2,900 rpm.
The two-pole motor provides the relatively high rotational speed required for the pump's compact single-stage centrifugal hydraulic design.
The LPP series uses a Class F motor insulation system and IP55 enclosure protection, with IE2 efficiency specified as standard and IE3 available on request.
For commercial and industrial installations, the motor should be connected through an appropriately rated motor protection device and overload protection.
DN50 Flanged Construction
The "50" in LPP 50 corresponds to the nominal DN50 connection size.
The pump uses flanged connections rather than the threaded connections commonly found on small domestic circulators.
The published LPP50 dimensional data gives an installation length of 340 mm for the LPP50-12-1.1/2.
This makes the following dimensions particularly important when replacing an existing pump:
- DN50 pipe size
- Flange standard
- Flange diameter
- Bolt-hole arrangement
- 340 mm installation length
- Vertical clearance
- Motor clearance
- Pipe-support requirements
The LPP series uses flanges conforming to applicable EN 1092 / DIN 2576 standards in the published LEO specifications.
Vertical In-Line Design
The pump's vertical in-line configuration provides several installation advantages.
The suction and discharge connections are arranged along the same pipe axis, allowing the pump to be installed directly into the system piping.
This design is useful for:
- HVAC plant rooms
- Central heating systems
- Chilled-water systems
- Boiler circulation
- Cooling-water systems
- Commercial buildings
- Industrial process-water systems
The compact arrangement can reduce the floor area required compared with some horizontally mounted centrifugal-pump configurations.
Single-Stage Centrifugal Construction
The LPP 50-12-1.1/2 uses a single-stage centrifugal hydraulic design.
Water enters the impeller at the suction side, receives energy from the rotating impeller and exits through the pump discharge with increased pressure.
The single-stage configuration is appropriate for applications where the required head can be achieved without multiple impeller stages.
LEO describes the LPP as a single-stage, close-coupled in-line centrifugal pump incorporating a mechanical shaft seal and hydraulically balanced impeller.
Maximum Flow – 26 m³/h
The published maximum flow for the LPP 50-12-1.1/2 is approximately:
26 m³/h
This is equivalent to approximately:
433 L/min
The actual flow available in an installation will depend on the system resistance.
Factors affecting actual flow include:
- Pipe diameter
- Pipe length
- Elbows and bends
- Isolation valves
- Control valves
- Filters
- Heat exchangers
- Cooling coils
- Boilers
- Radiators
- Static pressure
- System elevation
The 20 m³/h rated flow is therefore more useful for describing the intended nominal duty than the 26 m³/h maximum value.
Maximum Head – 15 m
The pump has a published maximum head of approximately 15 m.
The rated head is 12 m at the nominal 20 m³/h operating point.
A 15 m water column corresponds to approximately 1.47 bar of water pressure under standard conditions.
The actual head generated at a particular flow rate must be determined from the pump's performance curve.
Temperature Capability
The LPP series is designed for water circulation at temperatures up to approximately 90°C.
This makes the LPP 50-12-1.1/2 suitable for many:
- Hot-water heating systems
- Central heating systems
- Boiler circulation systems
- HVAC systems
- Cooling-water systems
- Industrial hot-water applications
LEO's LPP specification identifies a liquid-temperature range extending to approximately 90°C.
For high-temperature applications, the actual system pressure, fluid temperature and mechanical-seal specification should be checked together rather than evaluating temperature independently.
Maximum Working Pressure
The published LPP50 specifications indicate a maximum working pressure of approximately 16 bar.
This allows the pump to be considered for pressurised commercial and industrial circulation systems, provided the complete piping system, valves, flanges and other components are rated appropriately.
NPSH Requirement
The LPP50-12-1.1/2 has a published NPSH requirement of approximately 2 m.
NPSH becomes particularly important when:
- Pumping hot water
- Pumping from an open tank
- The suction pipe is long
- The suction pipe is undersized
- There are excessive suction-side fittings
- The available inlet pressure is low
Insufficient NPSH can result in cavitation, which may cause noise, vibration, loss of performance and premature hydraulic-component damage.
Recommended Applications
The LEO LPP 50-12-1.1/2 is suitable for:
- Central heating circulation
- HVAC circulation
- Air-conditioning cooling-water circulation
- Chilled-water circulation
- Hot-water circulation
- Boiler circulation
- Heat-exchanger circulation
- Cooling-water systems
- Commercial building HVAC
- Water-treatment systems
- Waterworks transfer
- Main-pipe pressure boosting
- Industrial process-water circulation
- Industrial auxiliary systems
- Washing and cleaning systems
- General clean-water circulation
LEO's official LPP application list includes HVAC hot-water circulation, boiler mixing and temperature mixing, air-conditioning cooling-water circulation, waterworks filtration and transfer, main-pipe pressure boosting, boiler feeding, cooling-water circulation, water treatment and industrial auxiliary systems.
Suitable Fluids
The LPP 50-12-1.1/2 is primarily intended for clean water and liquids with physical and chemical characteristics similar to water.
Typical applications include:
- Clean water
- Heating water
- Cooling water
- Chilled water
- Treated process water
- Boiler circulation water
- Compatible water-based fluids
It is not intended for heavily abrasive, highly contaminated or solids-laden fluids unless the specific pump configuration and materials have been approved for that medium.
Motor Protection – IP55
The motor is rated IP55.
This provides protection against dust ingress sufficient to prevent harmful deposits and protection against water jets from any direction.
This makes the LPP motor more appropriate for commercial plant rooms and industrial environments than many small residential circulators with lower enclosure ratings. LEO specifies IP55 protection for the LPP series.
Class F Insulation
The motor uses Class F insulation.
Class F insulation provides a higher thermal capability than Class B insulation and is commonly used in commercial and industrial pump motors.
Combined with the IP55 motor enclosure, the LPP 50-12-1.1/2 is configured for demanding circulation applications.
Installation Considerations
The LPP 50-12-1.1/2 should be installed by qualified personnel.
Before installation:
- Confirm the pump model and hydraulic duty.
- Verify DN50 flange compatibility.
- Confirm the 340 mm installation length.
- Check the flange standard and bolt-hole arrangement.
- Ensure the pipework is properly supported.
- Install the pump in the correct flow direction.
- Fill the system with the appropriate liquid.
- Vent trapped air from the system.
- Confirm the motor is suitable for the available three-phase supply.
- Check motor rotation during commissioning.
- Verify operating current against the motor nameplate.
- Ensure adequate motor ventilation.
- Prevent dry running.
- Check all flange connections for leakage.
The pump should not be used to compensate for incorrectly sized pipework or inadequate system design.
Pump Selection
For a proper LPP 50-12-1.1/2 selection, determine the system's:
Required flow rate (Q)
Required total dynamic head (H)
Fluid temperature
Fluid characteristics
System operating pressure
Available electrical supply
For example, if the system requires approximately 20 m³/h at 12 m head, the LPP 50-12-1.1/2 is aligned with its published nominal duty point.
If the system requires significantly more or less flow/head, the pump curve should be checked rather than relying solely on the model number.
Oversizing can result in excessive flow velocity, system noise and unnecessary energy consumption. Undersizing can result in insufficient flow through heat exchangers, coils, boilers or terminal units.
Key Advantages
The LEO LPP 50-12-1.1/2 offers:
- 1.1 kW motor for medium-duty circulation.
- 20 m³/h nominal flow.
- 12 m nominal head.
- 26 m³/h maximum flow.
- 15 m maximum head.
- 2,900 rpm two-pole motor.
- DN50 flanged connections.
- 340 mm installation length.
- Vertical in-line configuration for space-efficient installation.
- Single-stage centrifugal design.
- Close-coupled construction.
- Class F motor insulation.
- IP55 motor protection.
- 16 bar maximum working pressure.
- Up to 90°C liquid temperature.
- Suitable for HVAC, heating, cooling and industrial circulation.
Performance Summary
| Parameter | LEO LPP 50-12-1.1/2 |
|---|---|
| Motor Power | 1.1 kW |
| Approx. Horsepower | 1.5 HP |
| Speed | 2,900 rpm |
| Rated Flow | 20 m³/h |
| Rated Flow | ≈333 L/min |
| Rated Head | 12 m |
| Maximum Flow | 26 m³/h |
| Maximum Flow | ≈433 L/min |
| Maximum Head | 15 m |
| NPSH | Approx. 2 m |
| Connection | DN50 |
| Connection Type | Flanged |
| Installation Length | 340 mm |
| Maximum Fluid Temperature | 90°C |
| Maximum Working Pressure | 16 bar |
| Insulation Class | F |
| Protection Class | IP55 |
| Motor Efficiency | IE2 |
| IE3 | Available on request |
| Motor Type | 2-Pole / 3-Phase |
| Pump Type | Vertical In-Line Centrifugal |
The core hydraulic specifications above are taken from the published LEO LPP50 model table and LPP-series documentation.
Website Product Description
LEO LPP 50-12-1.1/2 Vertical In-Line Circulation Pump 1.1kW is a robust single-stage centrifugal pump designed for medium-duty circulation and water-transfer applications. Equipped with a 1.1 kW two-pole motor operating at approximately 2,900 rpm, the pump provides a rated flow of 20 m³/h at 12 m head, with maximum performance of approximately 26 m³/h flow and 15 m head.
The pump features a vertical in-line configuration and DN50 flanged connections, making it suitable for direct installation into commercial and industrial piping systems. Its 340 mm installation length allows it to be integrated into compatible HVAC, heating and cooling-water systems while maintaining a relatively compact footprint.
The LPP 50-12-1.1/2 is designed for hot-water circulation, central heating, HVAC, air-conditioning cooling-water circulation, boiler systems, water treatment, waterworks transfer, pressure boosting and industrial auxiliary applications. It is specified for liquid temperatures up to approximately 90°C, maximum working pressure of 16 bar, Class F motor insulation and IP55 protection.
With its 1.1 kW motor, 20 m³/h rated capacity, 12 m rated head, DN50 flanged construction and vertical in-line design, the LEO LPP 50-12-1.1/2 is suitable for commercial buildings, mechanical plant rooms, heating installations and industrial water-circulation systems.
SEO Product Title
LEO LPP 50-12-1.1/2 Vertical In-Line Circulation Pump 1.1kW 3-Phase DN50
SEO Meta Description
LEO LPP 50-12-1.1/2 vertical in-line circulation pump with 1.1kW motor, 20m³/h rated flow and 12m head. DN50 flanged pump for HVAC, heating, cooling and industrial systems.
Inquiry - LEO CIRCULATION PUMPS - LPP 50-12-1.1/2