B116, C15 Jalan Haji Ahmad, Perkampungan Seri Setali, 25300 Kuantan, Pahang, Malaysia.

+6019-323 7617

kstoolsdepot@gmail.com


Share:


LEO CIRCULATION PUMPS - LPP 50-21-2.2/2



The LEO LPP 50-21-2.2/2 is a single-stage, close-coupled vertical in-line centrifugal pump designed for medium-to-heavy-duty water circulation and transfer applications. It is suitable for HVAC systems, hot-water heating, boiler circulation, chilled-water systems, cooling-water circulation, water treatment, waterworks, pressure boosting and industrial auxiliary systems. LEO's LPP50 technical range includes this model with a 2.2 kW motor, 24 m³/h nominal flow and 21 m nominal head.

The pump uses a DN50 / 2-inch flanged connection, operates at approximately 2,900 rpm, and has a published maximum capacity of 35 m³/h with a maximum head of approximately 25 m. The published dimensional drawing gives a 340 mm installation length for the LPP50-21-2.2/2.

Product Specifications

Specification LEO LPP 50-21-2.2/2
Brand LEO
Model LPP 50-21-2.2/2
Product Type Vertical In-Line Circulation Pump
Pump Type Single-Stage Centrifugal
Design Close-Coupled
Motor Power 2.2 kW
Approx. Motor Power 3 HP
Motor Configuration 2-Pole
Rated Speed 2,900 rpm
Rated Flow 24 m³/h
Rated Head 21 m
Maximum Flow 35 m³/h
Maximum Head 25 m
NPSH Required Approx. 2 m
Connection Size DN50
Connection 2" × 2" Flanged
Installation Length 340 mm
Electrical Supply 3-Phase
Typical Voltage 380–415 V
Frequency 50 Hz
Maximum Liquid Temperature 90°C
Maximum Working Pressure 16 bar
Maximum Ambient Temperature Up to 50°C*
Motor Insulation Class F
Motor Protection IP55
Motor Efficiency IE2
Higher Efficiency Option IE3 available on request
Impeller Cast Iron / Stainless Steel option
Shaft Stainless Steel
Pump Body Cast Iron
Application Heating / HVAC / Cooling / Industrial Water

The LEO technical table lists 2.2 kW, 2,900 rpm, 24 m³/h nominal flow, 21 m nominal head, 35 m³/h maximum flow, 25 m maximum head and approximately 2 m NPSH for the LPP50-21-2.2/2.

*Some commercial listings specify an ambient-temperature limit of 50°C, while the broader LPP documentation may specify different conditions. Check the actual nameplate/datasheet supplied with the unit for final installation specifications.

Model Code Explanation

The designation LPP 50-21-2.2/2 generally identifies:

  • LPP – LEO vertical in-line pump series
  • 50 – nominal DN50 pump connection
  • 21 – nominal head of approximately 21 m
  • 2.2 – 2.2 kW motor power
  • /2 – 2-pole motor configuration

This interpretation is consistent with LEO's published LPP50 model table, which lists the LPP50-21-2.2/2 alongside other LPP50 models according to motor power, nominal head and hydraulic capacity.

Product Overview

The LPP 50-21-2.2/2 is designed for direct in-line installation within a water-piping system. Its vertical in-line arrangement places the suction and discharge connections along the same pipe axis, making it suitable for mechanical rooms and plant rooms where efficient use of floor space is important.

The pump is particularly suited to applications requiring substantially greater circulation capacity and head than compact domestic circulators. Its 24 m³/h rated flow and 21 m rated head make it suitable for larger heating, cooling and HVAC circuits.

Rated Hydraulic Performance

The nominal operating point is:

Flow: 24 m³/h
Head: 21 m
Motor: 2.2 kW
Speed: 2,900 rpm

24 m³/h is approximately:

400 L/min

The published maximum values are:

Maximum flow: 35 m³/h
Maximum head: 25 m

These maximum values represent different portions of the pump's performance curve and should not be interpreted as 35 m³/h at 25 m head. The actual operating point must be determined from the hydraulic curve and system resistance.

Hydraulic Performance

The LPP 50-21-2.2/2 provides considerably higher hydraulic performance than the LPP 50-12-1.1/2.

Parameter LPP 50-21-2.2/2
Rated Flow 24 m³/h
Rated Flow ≈400 L/min
Rated Head 21 m
Maximum Flow 35 m³/h
Maximum Flow ≈583 L/min
Maximum Head 25 m
Motor Power 2.2 kW
Speed 2,900 rpm

LEO's published LPP50 table confirms the 24 m³/h / 21 m nominal duty point and 35 m³/h / 25 m maximum performance.

2.2 kW Motor

The pump is equipped with a 2.2 kW three-phase motor, equivalent to approximately 3 HP.

The motor is a 2-pole design operating at approximately 2,900 rpm at 50 Hz. This high-speed motor configuration provides the rotational speed required by the single-stage centrifugal hydraulic assembly.

Commercial Malaysian listings specify the pump as 2.2 kW, 415 V, 50 Hz, making it suitable for standard three-phase industrial electrical systems in Malaysia.

Appropriate motor protection, overload protection and electrical isolation should be provided during installation.

DN50 / 2-Inch Flanged Connection

The LPP 50-21-2.2/2 uses DN50 / 2-inch flanged connections.

This makes it suitable for larger circulation pipelines used in:

  • HVAC plants
  • Central heating
  • Chilled-water systems
  • Boiler circuits
  • Cooling systems
  • Industrial water circulation

A published Malaysian listing identifies the suction/discharge connection as 2" × 2", while the LEO LPP50 series is classified as DN50.

Before replacing an existing pump, verify:

  • DN50 pipe size
  • Flange standard
  • Flange outside diameter
  • Bolt-hole pattern
  • Face-to-face dimension
  • Pipe alignment
  • Available motor clearance

340 mm Installation Length

The published LEO dimensional drawing specifies an L1 installation length of 340 mm for the LPP50-21-2.2/2.

This dimension is particularly important for replacement applications.

The pump should not be selected solely because the connection is DN50. The existing installation should also have sufficient space for the 340 mm pump length, plus adequate clearance around the motor for ventilation and maintenance.

Vertical In-Line Construction

The vertical in-line arrangement allows the pump to be installed directly into the system piping.

Major advantages include:

  • Reduced floor-space requirements
  • Straightforward pipe routing
  • Compact plant-room installation
  • Suitable for HVAC risers and circulation loops
  • Convenient integration into commercial piping systems
  • Direct in-line suction and discharge arrangement

The LPP series is specifically categorized by LEO as a vertical in-line circulation pump.

Single-Stage Centrifugal Design

The LPP 50-21-2.2/2 uses a single-stage centrifugal hydraulic design.

Water enters through the suction side, is accelerated by the rotating impeller and exits through the discharge side at increased pressure.

The single-stage design provides a relatively simple hydraulic arrangement while the 2.2 kW motor provides the additional power required for the model's higher 21 m rated head.

Pump Construction

The LPP50 series incorporates robust materials for commercial and industrial water circulation.

Pump Body:
LEO's technical material table identifies HT200/QT400 cast iron for the pump housing/support components.

Impeller:
The standard configuration uses HT200 cast iron, while an AISI 304 stainless-steel impeller option is available for certain configurations upon request.

Shaft:
The shaft is specified as AISI 304 stainless steel combined with 45# steel construction in the LEO technical material table.

Mechanical Seal:
The pump uses a mechanical shaft seal designed to prevent leakage between the rotating shaft and stationary pump housing.

Maximum Flow – 35 m³/h

The published maximum flow for the LPP 50-21-2.2/2 is approximately:

35 m³/h

Equivalent to approximately:

583 L/min

This represents the upper end of the pump's published hydraulic capacity. The actual flow in an installed system will be determined by the intersection between the pump curve and system curve.

The system's resistance is influenced by pipe length, pipe diameter, valves, elbows, heat exchangers, filters, coils and other components.

Maximum Head – 25 m

The LPP 50-21-2.2/2 has a published maximum head of approximately 25 m, with a nominal rated head of 21 m.

A 25 m water column corresponds to approximately 2.45 bar of water pressure under standard conditions.

The actual pressure generated at a particular flow rate will be lower than the maximum shut-off head, depending on the pump operating point.

Maximum Operating Pressure – 16 bar

Published LPP50 product information specifies a maximum operating pressure of 16 bar.

This makes the pump suitable for many pressurised commercial and industrial systems, provided the piping, valves, flanges and other components are also rated for the required pressure and temperature.

Liquid Temperature

The LPP 50-21-2.2/2 is specified for water temperatures up to approximately 90°C.

This allows applications including:

  • Hot-water heating
  • Boiler circulation
  • Central heating
  • HVAC heating circuits
  • Heat-exchanger circulation
  • Cooling-water circulation

The actual temperature-pressure combination should always remain within the manufacturer's limits.

NPSH Requirement

The LEO technical table specifies approximately 2 m NPSH required for the LPP50-21-2.2/2.

Adequate suction conditions are essential to prevent cavitation.

Cavitation can cause:

  • Hydraulic noise
  • Vibration
  • Loss of flow/head
  • Impeller erosion
  • Mechanical-seal problems
  • Reduced service life

This is particularly important when circulating hot water because increased temperature reduces the available margin against vapor formation.

Recommended Applications

The LEO LPP 50-21-2.2/2 is suitable for:

  • Central heating systems
  • Hot-water circulation
  • Boiler circulation
  • HVAC circulation
  • Chilled-water systems
  • Air-conditioning cooling-water circulation
  • Fan-coil systems
  • Cooling-water circulation
  • Heat-exchanger systems
  • Underfloor heating
  • Water-treatment systems
  • Waterworks
  • Water filtration and transfer
  • Main-pipeline pressure boosting
  • Industrial process-water circulation
  • Industrial auxiliary systems
  • Fire-fighting water systems where the complete system design and certification requirements are met
  • Washing and cleaning systems

LEO's LPP application information includes heating and HVAC hot-water circulation, boiler applications, air-conditioning cooling-water circulation, waterworks filtration and transfer, pressure boosting, boiler feeding, water treatment and industrial auxiliary applications.

Suitable Fluids

The pump is primarily intended for clean water and liquids with physical and chemical characteristics similar to water.

Suitable fluids can include:

  • Clean heating water
  • Chilled water
  • Cooling water
  • Treated industrial water
  • Boiler circulation water
  • Compatible water-based fluids

The standard pump should not be used for abrasive slurry, sewage or heavily contaminated liquids without confirming material and seal compatibility.

Motor Protection

The motor has:

Protection Class: IP55
Insulation Class: F

IP55 provides protection against harmful dust deposits and water jets from any direction, making the motor suitable for many commercial and industrial plant-room environments.

The Class F insulation system provides increased thermal capability for demanding motor applications. LEO specifies these characteristics for the LPP series.

Electrical Requirements

The LPP 50-21-2.2/2 is a three-phase motor.

Common specifications for this model are:

Voltage: 380–415 V
Frequency: 50 Hz
Motor Power: 2.2 kW
Speed: approximately 2,900 rpm

A Malaysian product listing specifically identifies the model as 2.2 kW / 415 V / 50 Hz.

The electrical installation should include suitable:

  • Motor overload protection
  • Short-circuit protection
  • Isolator
  • Contactor or appropriate motor starter
  • Earthing
  • Phase-sequence/rotation verification

Installation Considerations

Before installing the LEO LPP 50-21-2.2/2:

  1. Confirm the required hydraulic duty.
  2. Verify the DN50 flange dimensions.
  3. Confirm the 340 mm installation length.
  4. Check the pipework alignment.
  5. Ensure the pipework is independently supported.
  6. Do not use the pump casing to support heavy or misaligned pipework.
  7. Install the pump according to the specified flow direction.
  8. Fill the system before starting.
  9. Vent trapped air.
  10. Confirm adequate suction pressure.
  11. Verify three-phase motor rotation.
  12. Check operating current after commissioning.
  13. Ensure the motor has sufficient ventilation.
  14. Protect the pump from dry running.
  15. Inspect the flange connections for leakage.

Pump Selection

Correct selection should be based on the actual system duty point rather than simply selecting the pump based on maximum flow or maximum head.

Determine:

Required flow rate (Q)
Required total dynamic head (H)
Fluid temperature
System operating pressure
Fluid characteristics
Electrical supply

For example, if a system requires approximately 24 m³/h at 21 m head, the LPP 50-21-2.2/2 closely matches its published nominal duty point.

If the required duty is significantly different, the pump curve should be checked before purchase.

An oversized pump may produce excessive flow, noise and energy consumption. An undersized pump may not provide sufficient circulation through heating coils, chillers, boilers or heat exchangers.

LPP 50-21-2.2/2 vs LPP 50-12-1.1/2

Specification LPP 50-12-1.1/2 LPP 50-21-2.2/2
Motor 1.1 kW 2.2 kW
Speed 2,900 rpm 2,900 rpm
Rated Flow 20 m³/h 24 m³/h
Rated Head 12 m 21 m
Maximum Flow 26 m³/h 35 m³/h
Maximum Head 15 m 25 m
Connection DN50 DN50
Installation Length 340 mm 340 mm
Pump Type Vertical In-Line Vertical In-Line

The LPP 50-21-2.2/2 therefore provides substantially greater head and hydraulic capacity than the LPP 50-12-1.1/2, making it better suited to systems with higher pressure losses or greater circulation requirements. The LEO LPP50 model table confirms the respective performance figures.

Key Advantages

  1. 2.2 kW motor for higher-capacity circulation.
  2. 3 HP approximate motor rating.
  3. 24 m³/h nominal flow.
  4. 21 m nominal head.
  5. 35 m³/h maximum flow.
  6. 25 m maximum head.
  7. 2,900 rpm two-pole motor.
  8. DN50 / 2-inch flanged connections.
  9. 340 mm installation length.
  10. Vertical in-line configuration for compact installation.
  11. Single-stage centrifugal design.
  12. Close-coupled construction.
  13. Stainless-steel shaft.
  14. Cast-iron impeller/body construction.
  15. Class F motor insulation.
  16. IP55 motor protection.
  17. 16 bar maximum operating pressure.
  18. Up to 90°C liquid temperature.
  19. Suitable for heating, HVAC, cooling and industrial applications.

Performance Summary

Parameter LEO LPP 50-21-2.2/2
Motor Power 2.2 kW
Approx. Horsepower 3 HP
Motor 2-Pole / 3-Phase
Speed 2,900 rpm
Rated Flow 24 m³/h
Rated Flow ≈400 L/min
Rated Head 21 m
Maximum Flow 35 m³/h
Maximum Flow ≈583 L/min
Maximum Head 25 m
NPSH Required ≈2 m
Connection DN50 / 2"
Connection Type Flanged
Installation Length 340 mm
Maximum Liquid Temperature 90°C
Maximum Working Pressure 16 bar
Motor Insulation Class F
Motor Protection IP55
Pump Type Vertical In-Line Centrifugal
Pump Stages Single Stage

Website Product Description

LEO LPP 50-21-2.2/2 Vertical In-Line Circulation Pump 2.2kW is a heavy-duty single-stage centrifugal pump designed for hot-water circulation, HVAC, central heating, cooling-water systems, boiler circulation, water treatment and industrial applications. Powered by a 2.2 kW three-phase, 2-pole motor operating at approximately 2,900 rpm, the pump provides a rated flow of 24 m³/h at 21 m head, with maximum performance of approximately 35 m³/h flow and 25 m head.

The pump features a DN50 / 2-inch flanged connection and a 340 mm installation length, allowing it to be installed directly into compatible commercial and industrial pipework. Its vertical in-line configuration provides a compact solution for mechanical rooms, HVAC plant rooms and circulation systems where floor space is limited.

Constructed with a cast-iron pump body and impeller, stainless-steel shaft, mechanical seal, Class F motor insulation and IP55 protection, the LEO LPP 50-21-2.2/2 is designed for demanding water-circulation duties. It is suitable for liquid temperatures up to approximately 90°C and operating pressures up to 16 bar, subject to the complete system design.

Typical applications include boiler circulation, central heating, chilled-water circulation, HVAC systems, cooling-water circulation, fan-coil systems, heat exchangers, water-treatment systems, waterworks transfer, pressure boosting and industrial auxiliary circulation.

SEO Product Title

LEO LPP 50-21-2.2/2 Vertical In-Line Circulation Pump 2.2kW 3HP 3-Phase DN50

SEO Meta Description

LEO LPP 50-21-2.2/2 vertical in-line circulation pump with 2.2kW motor, 24m³/h rated flow and 21m head. DN50 flanged pump for HVAC, heating, cooling and industrial systems.



 Inquiry - LEO CIRCULATION PUMPS - LPP 50-21-2.2/2