B116, C15 Jalan Haji Ahmad, Perkampungan Seri Setali, 25300 Kuantan, Pahang, Malaysia.

+6019-323 7617

kstoolsdepot@gmail.com


Share:


LEO CIRCULATION PUMPS - LPP 100-24-15/2



The LEO LPP 100-24-15/2 is a single-stage, close-coupled vertical in-line centrifugal circulation pump designed for high-volume water circulation in HVAC, heating, cooling, water-supply and industrial systems. The LPP series uses a mechanical shaft seal, hydraulically balanced impeller and corrosion-resistant surface treatment, with a compact construction intended for relatively easy installation and maintenance.

For the exact LPP100-24-15/2, LEO's technical selection document specifies a 15 kW motor, 2,950 rpm rated speed, 150 m³/h rated flow and 24 m rated head, with a maximum impeller diameter of 158 mm. The supplied technical document identifies clean water at 20°C as the reference pumped medium.

A Malaysian product listing identifies the same model as a 15 kW / 415 V / 50 Hz, 4" × 4" in-line pump, with cast-iron impeller, maximum water temperature of 90°C, maximum operating pressure of 16 bar, and a listed flow range of 250–3,000 L/min.

Product Specifications

Specification LEO LPP 100-24-15/2
Brand LEO
Model LPP 100-24-15/2
Product Type Vertical In-Line Circulation Pump
Pump Type Single-Stage Centrifugal
Design Close-Coupled
Motor Power 15 kW
Approx. Motor Power 20 HP
Motor Configuration 2-Pole
Rated Speed 2,950 rpm
Rated Flow 150 m³/h
Rated Flow ≈2,500 L/min
Rated Head 24 m
Maximum Impeller Diameter 158 mm
Nominal Connection DN100 / 4"
Connection Type Flanged
Electrical Supply 3-Phase
Typical Malaysian Supply 415 V
Frequency 50 Hz
Pumped Medium Clean Water
Reference Water Temperature 20°C
Maximum Liquid Temperature Up to 90°C
Maximum Operating Pressure 16 bar
Motor Insulation Class F
Motor Protection IP55
Motor Efficiency IE2 standard; IE3 available
Pump Arrangement Vertical In-Line
Pump Stages Single Stage
Shaft Stainless Steel
Standard Impeller Cast Iron
Stainless Impeller Available for applicable configurations

The official LEO LPP documentation states that the LPP series covers flow rates up to 760 m³/h, heads up to 85 m, motor powers from 0.37 to 132 kW, liquid temperatures from 0°C to +90°C, maximum operating pressure of 16 bar, and ambient temperature up to 40°C.

Model Code Explanation

The model designation LPP 100-24-15/2 can generally be understood as:

  • LPP – LEO vertical in-line pump series
  • 100 – nominal DN100 / 4-inch connection
  • 24 – nominal head of approximately 24 m
  • 15 – 15 kW motor
  • /2 – 2-pole motor configuration

The model-specific technical document confirms the 15 kW / 2,950 rpm / 150 m³/h / 24 m specification.

Rated Hydraulic Performance

The published rated duty point is:

Rated Flow: 150 m³/h
Rated Head: 24 m
Motor Power: 15 kW
Speed: 2,950 rpm

A flow of 150 m³/h is equivalent to approximately:

2,500 L/min

or:

41.7 L/s

This places the LPP 100-24-15/2 in the high-flow segment of the LPP range.

The official performance document shows the pump curve extending to approximately 120 m³/h on the displayed curve, while its tabulated rated-flow field identifies 150 m³/h. Because the published curve and tabulated value do not appear perfectly aligned in the available document, the manufacturer's final selection curve should be used when specifying the exact operating point.

Hydraulic Performance

Parameter LEO LPP 100-24-15/2
Rated Flow 150 m³/h
Rated Flow ≈2,500 L/min
Rated Flow ≈41.7 L/s
Rated Head 24 m
Motor Power 15 kW
Approx. Motor Rating 20 HP
Speed 2,950 rpm
Max. Impeller Diameter 158 mm

The model's 24 m rated head corresponds to approximately 2.35 bar of water pressure under standard conditions.

The hydraulic head is not equivalent to the total pressure available at every flow rate. Actual head decreases or changes according to the pump's hydraulic performance curve and the system resistance.

15 kW Motor

The LPP 100-24-15/2 uses a substantial 15 kW three-phase motor, equivalent to approximately 20 HP.

At 50 Hz, the motor operates at approximately 2,950 rpm, indicating a 2-pole configuration.

This motor rating allows the pump to handle considerably higher hydraulic duty than smaller LPP models such as the LPP50 and LPP80 ranges.

For Malaysia, the commonly listed electrical configuration is:

415 V / 3-Phase / 50 Hz

The Malaysian listing specifically identifies the model as 15 kW / 415 V / 50 Hz.

A suitable motor protection system should include:

  • Short-circuit protection
  • Overload protection
  • Appropriate motor starter or VFD
  • Electrical isolator
  • Correct earthing
  • Phase-sequence verification

DN100 / 4-Inch Connection

The 100 designation indicates a nominal DN100 / 4-inch connection.

The Malaysian listing specifies a 4" × 4" connection configuration.

This large connection size is appropriate for high-volume circulation applications where relatively large quantities of water need to be moved without excessive pipe friction.

Typical DN100 applications include:

  • Large commercial HVAC systems
  • Chilled-water plants
  • Cooling-water systems
  • Central heating plants
  • Boiler circulation
  • Industrial process-water systems
  • Water-treatment systems
  • Large building mechanical systems

For replacement installations, the actual flange dimensions and standard should be verified rather than assuming that every DN100 flange is dimensionally interchangeable.

Vertical In-Line Construction

The LPP 100-24-15/2 is a vertical in-line pump, meaning the suction and discharge connections are arranged for direct integration into the pipeline.

This design is particularly useful where floor space is limited.

Advantages include:

  • Compact footprint
  • Direct pipe installation
  • Reduced floor-space requirements
  • Suitable for plant rooms
  • Suitable for HVAC mechanical rooms
  • Convenient integration into large circulation loops
  • Simplified piping layout

LEO describes the LPP series as compact and easy to maintain, with a close-coupled in-line configuration.

Single-Stage Centrifugal Design

The pump uses a single-stage centrifugal hydraulic system.

The impeller transfers rotational energy from the motor to the water, generating the required circulation flow and pressure.

The LPP 100-24-15/2 is primarily a high-flow, moderate-head pump, rather than a high-pressure multistage pump.

Its 150 m³/h rated flow makes it particularly appropriate for systems where large water volumes must circulate continuously.

High-Flow Capacity

At its published rated point, the pump provides:

150 m³/h

Equivalent to:

  • 2,500 L/min
  • 41.7 L/s
  • 36,000 m³/day if operating continuously at the rated flow

The last figure is a theoretical continuous-volume calculation and should not be interpreted as a guaranteed daily output under actual system conditions.

The Malaysian product listing gives a broader commercial flow range of 250–3,000 L/min, equivalent to approximately 15–180 m³/h, together with a head range of approximately 30–20 m.

Because this commercial listing and the official selection document present the hydraulic information differently, the manufacturer's pump curve should take precedence for engineering selection.

Rated Head – 24 m

The exact model's technical document specifies a rated head of 24 m.

A 24 m water column corresponds to approximately:

2.35 bar

under standard water conditions.

The pump's actual discharge pressure depends on the suction pressure, flow rate, system resistance and operating point.

Maximum Impeller Diameter

The official technical document specifies a maximum impeller diameter of 158 mm for the LPP100-24-15/2.

Impeller diameter is an important parameter in centrifugal-pump performance because it directly affects the pump's head, flow and power characteristics.

The actual supplied impeller configuration should be confirmed from the pump nameplate and manufacturer's documentation.

Pumped Medium

The official technical selection document uses clean water as the reference pumped medium, with:

Medium: Clean water
Reference temperature: 20°C
Density: 1,000 kg/m³
Viscosity: 1 mm²/s

The pump should therefore primarily be used for clean or appropriately treated water unless the manufacturer confirms material and mechanical-seal compatibility with another liquid.

Temperature Capability

The LEO LPP series is designed for applications involving both heating and cooling water. LEO specifies an overall liquid-temperature range of 0°C to +90°C for the LPP series.

This allows applications such as:

  • Hot-water circulation
  • Central heating
  • Boiler systems
  • HVAC heating
  • Chilled-water circulation
  • Cooling-water circulation
  • Heat-exchanger systems

A Malaysian listing for the exact model also specifies a maximum water temperature of 90°C.

Maximum Operating Pressure

The LEO LPP series is specified for a maximum operating pressure of 16 bar.

The 16-bar rating applies to the pump's specified operating conditions. The complete installation must also have compatible:

  • Pipes
  • Flanges
  • Valves
  • Gaskets
  • Heat exchangers
  • Expansion vessels
  • Other pressure-containing components

Motor Protection

The LPP series uses:

Insulation Class: F
Protection Class: IP55

LEO also specifies IE2 motor efficiency as standard, with IE3 available upon request for the LPP series.

IP55 protection provides protection against dust ingress and water jets, making the motor suitable for many indoor mechanical-room and industrial environments.

Recommended Applications

The LEO LPP series is intended for a broad range of commercial and industrial applications.

For the high-capacity LPP 100-24-15/2, suitable applications include:

  • Large HVAC circulation
  • Chilled-water circulation
  • Cooling-water circulation
  • Central heating
  • Boiler circulation
  • Hot-water circulation
  • Heat-exchanger circulation
  • Commercial building HVAC
  • Industrial process-water circulation
  • Water-treatment systems
  • Waterworks
  • Water filtration and transfer
  • Main-pipeline pressure boosting
  • Industrial washing and cleaning
  • Boiler feeding
  • Industrial auxiliary systems
  • Fire-fighting applications, subject to applicable system certification and requirements

HVAC Applications

The LPP 100-24-15/2 is well suited to large HVAC circulation systems.

In a chilled-water installation, it can be used to circulate water between:

Chiller → Pump → Distribution Header → AHU/FCU/Heat Exchanger → Return Header → Chiller

In a heating installation, it can circulate water between:

Boiler → Pump → Heating Header → Heat Exchangers/Coils → Return → Boiler

The actual pump selection must be based on the system's required flow and total dynamic head.

Cooling-Water Applications

The high flow capacity makes the pump suitable for cooling-water circulation where large quantities of water must be moved through:

  • Cooling systems
  • Heat exchangers
  • Condenser circuits
  • Industrial cooling loops
  • HVAC cooling systems

The pump's DN100 connection helps accommodate the larger pipework normally associated with these high-flow applications.

Water-Supply and Transfer Applications

LEO also identifies waterworks filtration and transfer and main-pipeline pressure boosting among LPP applications.

The LPP 100-24-15/2 can therefore be considered for:

  • Water-treatment circulation
  • Filtration systems
  • Transfer systems
  • Main-line circulation
  • Industrial water distribution

The actual application should be checked against the required duty point and system pressure.

Pump Construction

The LPP series incorporates:

  • Close-coupled construction
  • Mechanical shaft seal
  • Hydraulically balanced impeller
  • Anti-corrosion surface treatment
  • Stainless-steel shaft
  • Cast-iron or stainless-steel impeller options

LEO specifically describes the series as using a mechanical shaft seal, hydraulically balanced impeller and anti-corrosion surface treatment.

The Malaysian listing for the exact LPP100-24-15/2 identifies the supplied configuration as having a cast-iron impeller and stainless-steel shaft.

Mechanical Shaft Seal

The LPP series uses a mechanical shaft seal to minimize leakage around the rotating shaft.

LEO also describes dry-running protection associated with the mechanical-seal arrangement in the exact-model Malaysian listing.

Nevertheless, the pump should not intentionally be operated dry. The system should be correctly filled and vented before commissioning.

Installation Considerations

Because the LPP 100-24-15/2 is a large 15 kW / DN100 pump, installation should be carried out carefully.

Recommended installation checks include:

  1. Confirm the system's required flow.
  2. Confirm the required total dynamic head.
  3. Verify DN100 flange dimensions.
  4. Verify the flange standard.
  5. Confirm the pump face-to-face dimension.
  6. Ensure suction and discharge pipework is independently supported.
  7. Avoid imposing pipe stress on the pump casing.
  8. Confirm the correct flow direction.
  9. Fill the system before starting.
  10. Vent trapped air.
  11. Confirm adequate suction conditions.
  12. Check the motor's rotation.
  13. Install appropriate electrical protection.
  14. Check operating current after startup.
  15. Check vibration and abnormal noise.
  16. Inspect flange connections for leakage.
  17. Prevent dry running.
  18. Ensure adequate motor ventilation.

Pump Selection

The most important factor when selecting the LPP 100-24-15/2 is the actual system duty point.

The required parameters are:

Q = Required Flow
H = Required Total Dynamic Head

Additional factors include:

  • Fluid temperature
  • Fluid density
  • Fluid viscosity
  • System pressure
  • Pipe diameter
  • Pipe length
  • Valve and fitting losses
  • Heat-exchanger losses
  • Electrical supply
  • Operating hours

The official technical document gives 150 m³/h at 24 m head as the rated point for this model.

For a system requiring approximately 150 m³/h at 24 m, this model is therefore a strong match, subject to confirmation from the manufacturer's final pump curve.

Important Hydraulic Data Note

There is a discrepancy between available published sources for this model.

The LEO technical selection document identifies:

Rated Flow: 150 m³/h
Rated Head: 24 m
Speed: 2,950 rpm
Maximum Impeller Diameter: 158 mm

A Malaysian commercial listing gives:

Flow Range: 250–3,000 L/min
Head: 30–20 m
15 kW / 415 V / 50 Hz
4" × 4" connection

For product-catalogue purposes, I recommend using the official LEO technical selection values of 150 m³/h and 24 m as the principal rated specifications, while treating the commercial flow/head range as performance-curve information rather than replacing the manufacturer's rated-point data.

Comparison With LPP80 Range

The LPP100-24-15/2 is substantially larger than the previously discussed LPP80-14-3/2.

Specification LPP 80-14-3/2 LPP 100-24-15/2
Motor 3 kW 15 kW
Approx. HP 4 HP 20 HP
Connection DN80 DN100
Rated Flow 55 m³/h 150 m³/h
Rated Head 14 m 24 m
Speed 2,900 rpm 2,950 rpm
Pump Type Vertical In-Line Vertical In-Line
Stages Single Single
Application Medium/high flow Very high flow

The LPP100-24-15/2 therefore represents a significantly higher-capacity pump, particularly in terms of motor power and hydraulic flow.

Key Advantages

  1. 15 kW high-power motor.
  2. Approximately 20 HP.
  3. 150 m³/h rated flow.
  4. Approximately 2,500 L/min rated flow.
  5. Approximately 41.7 L/s rated flow.
  6. 24 m rated head.
  7. 2,950 rpm rated speed.
  8. DN100 / 4-inch flanged connection.
  9. Vertical in-line configuration.
  10. Single-stage centrifugal design.
  11. Close-coupled construction.
  12. Hydraulically balanced impeller.
  13. Mechanical shaft seal.
  14. Stainless-steel shaft.
  15. Cast-iron impeller in the listed configuration.
  16. 16 bar maximum operating pressure.
  17. Up to 90°C liquid temperature.
  18. Class F insulation.
  19. IP55 motor protection.
  20. IE2 standard motor, with IE3 available on request.
  21. Suitable for large HVAC systems.
  22. Suitable for heating and cooling-water circulation.
  23. Suitable for waterworks and industrial applications.

Detailed Performance Summary

Parameter LEO LPP 100-24-15/2
Motor Power 15 kW
Approx. Horsepower 20 HP
Motor Type 2-Pole / 3-Phase
Rated Speed 2,950 rpm
Rated Flow 150 m³/h
Rated Flow 2,500 L/min
Rated Flow 41.7 L/s
Rated Head 24 m
Max. Impeller Diameter 158 mm
Connection DN100 / 4"
Connection Type Flanged
Pump Configuration Vertical In-Line
Pump Stages Single Stage
Reference Medium Clean Water
Reference Temperature 20°C
Maximum Liquid Temperature 90°C
Maximum Operating Pressure 16 bar
Motor Insulation Class F
Motor Protection IP55
Standard Motor Efficiency IE2
IE3 Option Available
Shaft Stainless Steel
Standard Impeller Cast Iron
Application HVAC / Heating / Cooling / Industrial

The exact-model hydraulic values are based primarily on LEO's technical selection document, while the construction and general operating specifications are supported by LEO's official LPP documentation.

Website Product Description

LEO LPP 100-24-15/2 Vertical In-Line Circulation Pump 15kW is a high-capacity single-stage centrifugal pump designed for large-scale HVAC, heating, cooling, water-supply and industrial circulation applications. Equipped with a 15 kW three-phase, 2-pole motor operating at approximately 2,950 rpm, the pump has a published rated flow of 150 m³/h at 24 m head, equivalent to approximately 2,500 L/min.

The pump features a DN100 / 4-inch flanged connection and compact vertical in-line construction, making it suitable for large commercial mechanical rooms, HVAC plants, central heating systems and industrial circulation networks. The LPP series uses a mechanical shaft seal, hydraulically balanced impeller, stainless-steel shaft and corrosion-resistant surface treatment for reliable water-circulation service.

The LEO LPP 100-24-15/2 is suitable for hot-water circulation, boiler systems, chilled-water and cooling-water circulation, heat exchangers, waterworks filtration and transfer, main-pipeline pressure boosting, water treatment and industrial auxiliary systems. The LPP series is rated for liquid temperatures up to 90°C and maximum operating pressure up to 16 bar, with Class F motor insulation and IP55 motor protection.

SEO Product Title

LEO LPP 100-24-15/2 Vertical In-Line Circulation Pump 15kW 20HP 3-Phase DN100

SEO Meta Description

LEO LPP 100-24-15/2 vertical in-line circulation pump with 15kW motor, 150m³/h rated flow and 24m head. DN100 4-inch pump for HVAC, heating, cooling and industrial systems.



 Inquiry - LEO CIRCULATION PUMPS - LPP 100-24-15/2