B116, C15 Jalan Haji Ahmad, Perkampungan Seri Setali, 25300 Kuantan, Pahang, Malaysia.

+6019-323 7617

kstoolsdepot@gmail.com


Share:


LEO VERTICAL MULTISTAGE PUMPS - EVPM 4-5



The LEO EVPM 4-5 is a vertical multistage centrifugal pump designed for clean-water supply, pressure boosting, high-rise buildings, industrial water systems, cleaning systems, high-pressure washing and irrigation. Its five-stage hydraulic configuration provides higher pressure while maintaining a compact vertical footprint.

The EVPM 4-5 is a 220V single-phase model with a 1.5 kW / 2.0 HP motor. The Malaysian product specification lists a flow range of 16.7–67 L/min and a head range of 58–29 m, with 1" × 1" inlet and outlet connections.

Product Specifications

Specification EVPM 4-5
Brand LEO
Product Series EVPM / EVP4
Model EVPM 4-5
Pump Type Vertical Multistage Centrifugal Pump
Voltage 220V
Phase Single Phase
Motor Power 1.5 kW / 2.0 HP
Number of Stages 5
Nominal Flow Class 4 m³/h
Published Flow Range 16.7 – 67 L/min
Approx. Flow Range 1 – 4 m³/h
Published Head Range 58 – 29 m
Inlet Size 1"
Outlet Size 1"
Inlet / Outlet 1" × 1"
Pump Orientation Vertical
Liquid Temperature 5°C – 60°C
Maximum Altitude Up to 1,000 m
Dimensions Approx. 420 × 315 × 800 mm
Weight Approx. 20.5 kg
Main Application Water Supply & Pressure Boosting

The above model-specific Malaysian specifications are published for the EVPM 4-5.

Hydraulic Performance

LEO's EVP4 technical data gives the EVPm4-5 performance curve as follows:

Flow Rate Approx. Head
0 L/min 61 m
16.7 L/min 58 m
33.3 L/min 57 m
50 L/min 55 m
66.7 L/min 48 m
83.3 L/min 28 m
100 L/min 20 m

The local EVPM 4-5 listing specifies the practical catalog range as 16.7–67 L/min with 58–29 m head, while the detailed EVP4 performance curve extends beyond this range.

The actual operating point depends on the system curve, pipe diameter, pipe length, elevation, fittings, valves and required water demand.

Key Features

• Five-stage vertical multistage centrifugal design
• 220V single-phase operation
• 1.5 kW / 2.0 HP motor
• 16.7–67 L/min published flow range
• Approximately 58–29 m head in the listed operating range
• 1" × 1" inlet and outlet connections
• Compact vertical installation
• Advanced hydraulic design
• Stable operation
• High hydraulic efficiency
• Rotatable water inlet and outlet
• Cast-iron water inlet and outlet with anti-rust treatment
• High-strength engineering-plastic flow-passage components
• Suitable for domestic, commercial and industrial water systems
• Suitable for pressure boosting and high-pressure water applications

Five-Stage Vertical Multistage Design

The EVPM 4-5 uses five hydraulic stages arranged vertically. Each stage contributes additional pressure to the pumped water, allowing the pump to achieve significantly higher head than a comparable single-stage pump.

The vertical arrangement also helps reduce the floor area required for installation. This makes the EVPM 4-5 appropriate for pump rooms, commercial buildings and other installations where available floor space is limited.

The EVP4 series is designed for a wide range of flow and head requirements and is used for water supply, overpressure systems, washing stations, heating and air-conditioning water circulation, water treatment and irrigation.

Hydraulic Construction

The EVPM series uses high-strength engineering-plastic components in the hydraulic flow passages, together with cast-iron water inlet and outlet components treated for corrosion resistance.

LEO's EVP4 documentation identifies cast-iron inlet and outlet components with anti-corrosion treatment and a construction intended for simplified installation and maintenance.

This construction provides a practical combination of mechanical strength, corrosion resistance and hydraulic performance for clean-water applications.

Rotatable Inlet and Outlet

The water inlet and outlet can be rotated to suit installation requirements. This allows the pump to be adapted to different pipework arrangements and can simplify installation where available space is restricted.

Connected pipework should be properly supported independently of the pump to prevent excessive mechanical stress on the pump connections.

Applications

The LEO EVPM 4-5 is suitable for:

• Domestic water supply
• Residential water pressure boosting
• Main-pipe pressure boosting
• High-rise building water supply
• Multi-storey buildings
• Water tank boosting
• Commercial buildings
• Hotels and accommodation facilities
• Industrial water systems
• Cleaning systems
• High-pressure washing systems
• Pressure tank systems
• Sprinkler irrigation
• Drip irrigation
• Air-conditioning water circulation
• Cooling-water systems
• Industrial cleaning
• General clean-water transfer

LEO officially identifies main-pipe and high-rise-building pressure boosting, industrial water systems, cleaning systems, high-pressure washing, firefighting, pressure tanks, sprinkler/drip irrigation, air-conditioning, cooling systems and industrial cleaning as EVP applications.

Pressure Boosting Applications

The EVPM 4-5 is suitable when the existing water supply does not provide sufficient pressure for the downstream system.

Typical applications include:

• Increasing water pressure to upper floors
• Boosting water from storage tanks
• Improving pressure in long pipe runs
• Supplying multiple water outlets
• Commercial building water supply
• High-pressure cleaning equipment
• Irrigation systems
• Industrial process-water supply
• Pressure tank systems

The five-stage configuration gives the EVPM 4-5 higher pressure capability than the EVPM 4-3 and EVPM 4-4 models.

Operating Conditions

The model-specific Malaysian listing specifies:

• Liquid temperature: 5°C to 60°C
• Maximum altitude: up to 1,000 m
• Voltage: 220V
• Motor power: 1.5 kW / 2.0 HP

LEO's EVP4 documentation additionally specifies a maximum ambient temperature of 40°C and maximum working pressure of 15 bar for the EVP4 family.

For actual installation, the limits stated on the specific pump nameplate and applicable LEO datasheet should take precedence.

Suitable Fluid

The EVPM 4-5 is primarily intended for clean water and compatible low-viscosity liquids.

Suitable applications include:

• Fresh water
• Clean storage-tank water
• Treated water
• General service water
• Clean irrigation water
• Cooling water within the specified temperature range

The pump should not be used for abrasive slurry, heavily contaminated water or liquids containing significant quantities of solids unless material compatibility has been specifically confirmed.

Installation Recommendations

For reliable operation:

• Install the pump vertically on a firm and level foundation.
• Use appropriately sized suction and discharge piping.
• Keep the suction pipe as short and direct as practical.
• Ensure suction connections are completely airtight.
• Avoid excessive restrictions on the suction side.
• Support all connected pipework independently.
• Install isolation valves where required for maintenance.
• Ensure an adequate water supply is available.
• Provide proper electrical grounding/earthing.
• Protect the motor from excessive moisture.
• Provide sufficient clearance around the pump for servicing.
• Avoid operating outside the recommended hydraulic range.

Maintenance

Recommended periodic maintenance includes:

• Checking for water leakage
• Inspecting suction and discharge connections
• Checking electrical terminals and wiring
• Monitoring operating pressure and flow
• Checking for abnormal vibration
• Checking for unusual operating noise
• Inspecting valves and pipework
• Ensuring adequate water supply
• Checking the mechanical seal for leakage
• Keeping the pump exterior clean
• Inspecting wear components when necessary

Advantages of EVPM 4-5

High Pressure Capability: The five-stage EVPM 4-5 provides approximately 58 m head at 16.7 L/min according to the detailed performance data.

2 HP Motor: Its 1.5 kW motor provides greater power than the EVPM 4-3 and EVPM 4-4, making it suitable for higher-pressure duties.

Five-Stage Configuration: Five hydraulic stages provide increased pressure capability while maintaining the compact vertical pump arrangement.

220V Single Phase: Suitable for installations with a compatible 220V single-phase electrical supply.

Compact Vertical Design: The vertical arrangement reduces floor-space requirements compared with many horizontal multistage configurations.

Flexible Installation: Rotatable inlet and outlet connections provide flexibility when connecting the pump to existing pipework.

Anti-Rust Treatment: The cast-iron water inlet and outlet receive anti-rust treatment.

Stable Hydraulic Operation: LEO specifies an advanced hydraulic model designed for stable operation and high efficiency.

EVPM 4-3 vs EVPM 4-4 vs EVPM 4-5

Specification EVPM 4-3 EVPM 4-4 EVPM 4-5
Voltage 220V 220V 220V
Motor Power 0.75 kW / 1 HP 1.0 kW / 1.5 HP 1.5 kW / 2 HP
Stages 3 4 5
Published Flow 16.7–67 L/min 16.7–67 L/min 16.7–67 L/min
Approx. Head Range 36–16 m 46–20 m 58–29 m
Inlet / Outlet 1" × 1" 1" × 1" 1" × 1"
Pressure Capability Lower Medium Higher

The EVPM 4-5 is therefore the higher-powered and higher-pressure model among these three configurations. The published EVP4 performance data confirms the progression from 3 to 5 stages and from 0.75 kW to 1.5 kW motor power.

Product Summary

The LEO EVPM 4-5 is a 220V, 1.5 kW / 2.0 HP vertical multistage centrifugal pump with a five-stage hydraulic configuration, 16.7–67 L/min published flow range, approximately 58–29 m head, and 1" × 1" inlet/outlet connections.

Its vertical construction, five-stage hydraulic design, flexible inlet/outlet arrangement and corrosion-treated water connections make it suitable for domestic and commercial water pressure boosting, high-rise buildings, industrial water systems, cleaning, high-pressure washing, irrigation and other clean-water applications.



 Inquiry - LEO VERTICAL MULTISTAGE PUMPS - EVPM 4-5