B116, C15 Jalan Haji Ahmad, Perkampungan Seri Setali, 25300 Kuantan, Pahang, Malaysia.

+6019-323 7617

kstoolsdepot@gmail.com


Share:


LEO MULTISTAGE CENTRIFUGAL PUMPS - 4ACM-100S



The LEO 4ACm100S is a four-stage stainless-steel horizontal multistage centrifugal pump designed for clean-water transfer, domestic water supply, pressure boosting, irrigation, high-rise water supply and long-distance water transfer. It is equipped with a 1 HP / 0.75 kW single-phase motor, 220V power supply, 1" × 1" inlet/outlet, and an AISI 304 stainless-steel shaft. LEO specifies the ACm-S series for clean water and liquids with similar physical and chemical properties.

Product Specifications

Specification 4ACm100S
Brand LEO
Model 4ACm100S / 4ACM-100S
Pump Type Stainless Steel Multistage Centrifugal Pump
Pump Orientation Horizontal
Number of Stages 4
Motor Power 0.75 kW
Motor Rating 1 HP
Motor Phase Single Phase
Voltage 220V
Frequency 50 Hz
Flow Range 5–90 L/min
Maximum Flow Approx. 5.4 m³/h
Head Range 43.5–5 m
Maximum Head Approx. 43.5 m
Maximum Suction Height 8 m
Suction Connection 1"
Discharge Connection 1"
Inlet / Outlet 1" × 1"
Shaft AISI 304 Stainless Steel
Pump Body Stainless Steel / treated cast-iron construction depending on component
Motor Winding Copper
Insulation Class F
Protection Class IPX4
Motor Protection Built-in Thermal Protector
Max. Ambient Temperature +40°C
Approx. Weight 13.5–14 kg

The Malaysian specifications list 5–90 L/min flow, 43.5–5 m head, 8 m maximum suction, 1 HP/0.75 kW power and 1" × 1" connections.

Four-Stage Multistage Design

The "4" in the 4ACm100S model designation represents the pump's four hydraulic stages.

The impellers operate in series, with each stage contributing additional pressure/head. This allows the 4ACm100S to produce substantially higher pressure than a conventional single-stage pump using a relatively compact motor.

The four-stage configuration is particularly suitable for:

  • Domestic pressure boosting
  • High-rise water supply
  • Long-distance water transfer
  • Irrigation
  • Elevated water transfer
  • Tank-to-building water supply
  • Industrial clean-water systems

Hydraulic Performance

The published performance range is:

Parameter 4ACm100S
Minimum listed flow 5 L/min
Maximum flow 90 L/min
Maximum flow Approx. 5.4 m³/h
Maximum head 43.5 m
High-flow head Approx. 5 m
Maximum suction 8 m

The 43.5 m maximum head and 90 L/min maximum flow are not simultaneous operating points. Actual flow and pressure depend on the system's total dynamic head, elevation, pipe friction and outlet requirements.

1 HP / 0.75 kW Motor

The 4ACm100S is fitted with a 1 HP / 0.75 kW single-phase motor operating on a 220V supply.

Motor features include:

  • 1 HP output
  • 0.75 kW motor power
  • 220V single phase
  • Copper winding
  • Built-in thermal protection
  • Class F insulation
  • IPX4 protection

A Malaysian product listing also specifies a C&U bearing, copper motor winding and built-in thermal protector.

Stainless-Steel Construction

The 4ACm100S belongs to LEO's ACm-S stainless-steel multistage series. LEO positions this series for clean-water applications, urban water supply, domestic water supply, high-rise buildings and long-distance water transfer.

The stainless-steel construction provides:

  • Improved corrosion resistance
  • Good durability in clean-water applications
  • Better resistance to surface corrosion
  • Suitable construction for domestic and commercial water systems
  • Easy cleaning and maintenance

The pump incorporates an AISI 304 stainless-steel shaft.

AISI 304 Stainless-Steel Shaft

The AISI 304 shaft provides corrosion resistance and mechanical strength while driving the four impeller stages.

This is particularly important in a multistage pump because the shaft operates through the complete hydraulic assembly.

1" × 1" Inlet & Outlet

The 4ACm100S uses:

Inlet: 1"
Outlet: 1"

This connection size is suitable for common domestic and irrigation pipework.

For best hydraulic performance:

  • Keep suction piping as short as practical.
  • Avoid unnecessary elbows.
  • Minimize restrictions.
  • Use airtight suction connections.
  • Support the pipe independently from the pump.

Maximum Suction Height – 8 m

The maximum specified suction height is 8 m.

Actual suction performance can be affected by:

  • Water temperature
  • Atmospheric pressure
  • Installation altitude
  • Suction pipe diameter
  • Suction pipe length
  • Pipe fittings
  • Water level
  • Air leakage
  • Friction losses

For suction-lift installations, the suction pipe should be properly sealed and installed as close to the water source as practical.

Suitable Fluids

LEO specifies the ACm-S series for clean water and other liquids with physical and chemical properties similar to water.

Suitable applications include:

  • Clean fresh water
  • Treated water
  • Tank water
  • Clean well water
  • Irrigation water
  • Domestic water
  • General service water

The pump is not intended for abrasive slurry or heavily contaminated wastewater unless the application has been specifically assessed for material compatibility.

Domestic Water Supply

The four-stage hydraulic design makes the 4ACm100S suitable for domestic systems requiring higher pressure.

Applications include:

  • House water supply
  • Water tank transfer
  • Residential pressure boosting
  • Shower pressure boosting
  • Garden water supply
  • Multi-outlet water distribution
  • Elevated water transfer

It can be used where a conventional single-stage pump cannot provide sufficient head.

High-Rise Water Supply

LEO specifically identifies the ACm-S series for high-rise building water supply.

The multistage design is useful for overcoming:

  • Building elevation
  • Pipe friction
  • Multiple fittings
  • Pressure losses
  • Long distribution lines

For high-rise applications, pump selection should be based on the calculated duty point rather than maximum head alone.

Irrigation Applications

The 4ACm100S can be used for clean-water irrigation systems where the required operating point falls within the pump curve.

Suitable applications include:

  • Garden irrigation
  • Lawn sprinklers
  • Nursery irrigation
  • Greenhouse irrigation
  • Small agricultural irrigation
  • Orchard irrigation
  • Tank-to-field transfer

The maximum listed flow is 90 L/min, equivalent to approximately 5.4 m³/h.

Long-Distance Water Transfer

The higher head capability makes the 4ACm100S suitable for transferring water through relatively long pipe runs.

The available pressure can be used to overcome:

  • Pipe friction
  • Elevation difference
  • Valves
  • Filters
  • Fittings
  • Other hydraulic resistance

Correct pipe sizing is still essential. An undersized suction or discharge pipe can significantly reduce actual performance.

Pressure Boosting

The four-stage arrangement provides useful pressure for:

  • Domestic booster systems
  • Tank outlet boosting
  • Irrigation pressure boosting
  • Long pipe runs
  • Commercial water distribution
  • Building water supply

The pump should be selected according to required flow rate and total dynamic head.

Motor Protection

The motor is specified with:

Insulation: Class F
Protection: IPX4
Thermal Protection: Built-in
Winding: Copper

The built-in thermal protector helps protect the motor against overheating under abnormal operating conditions.

Proper electrical protection, grounding and installation are still required.

Temperature Specifications

Regional specifications vary slightly for the ACm-S series. One Malaysian listing specifies:

Maximum liquid temperature: +60°C
Maximum ambient temperature: +40°C.

For your website, it is preferable to state the temperature rating according to the nameplate/manual supplied with your exact 4ACm100S stock, because LEO's regional documentation can differ.

Installation Recommendations

For reliable operation:

  • Install on a firm, level surface.
  • Place the pump close to the water source.
  • Keep suction piping short and direct.
  • Ensure suction connections are airtight.
  • Use suitable 1" suction piping.
  • Install a suitable foot valve/strainer where required.
  • Avoid excessive elbows and restrictions.
  • Support connected pipework independently.
  • Prime the pump before initial operation.
  • Ensure adequate water supply.
  • Provide proper electrical earthing.
  • Install suitable electrical protection.
  • Do not operate the pump dry.
  • Keep the pump within its specified operating range.

Maintenance

Recommended maintenance includes:

  • Checking for water leakage
  • Inspecting the mechanical seal
  • Checking suction-line air leakage
  • Cleaning the suction strainer
  • Inspecting impellers and diffusers
  • Checking vibration
  • Checking abnormal noise
  • Monitoring motor temperature
  • Checking electrical terminals
  • Monitoring pressure and flow
  • Inspecting valves and pipework

Dimensions & Weight

Current Malaysian listings give approximately:

Weight: 13.5–14 kg
Typical listed dimensions: approximately 38–43 cm long, depending on whether product or packaging dimensions are being quoted.

For installation drawings, use the manufacturer's dimensional drawing rather than packaging dimensions.

4ACm100S vs 3ACm100S

Specification 3ACm100S 4ACm100S
Number of Stages 3 4
Motor Power 0.60 kW 0.75 kW
Motor Rating 0.8 HP 1 HP
Voltage 220V 220V
Maximum Flow 78 L/min 90 L/min
Maximum Flow 4.68 m³/h 5.4 m³/h
Maximum Head 33.5 m 43.5 m
Maximum Suction 8 m 8 m
Connection 1" × 1" 1" × 1"
Main Advantage Lower power requirement Higher flow and head

The 4ACm100S provides a higher-power motor, additional hydraulic stage, higher maximum flow and higher maximum head compared with the 3ACm100S. The published 3ACm100S specification is 5–78 L/min and 33.5–5 m, while the 4ACm100S is 5–90 L/min and 43.5–5 m.

Key Advantages

Four-Stage Hydraulic Design: Provides higher pressure from a compact pump.

1 HP / 0.75 kW Motor: Suitable for higher-demand domestic and commercial water applications.

Up to 90 L/min Flow: Provides approximately 5.4 m³/h maximum listed flow.

Up to 43.5 m Head: Suitable for pressure boosting, elevated water transfer and long pipe runs.

Stainless-Steel Construction: Provides improved corrosion resistance for clean-water applications.

AISI 304 Shaft: Provides corrosion resistance and mechanical durability.

8 m Maximum Suction: Suitable for appropriate suction-lift installations.

220V Single Phase: Convenient for standard single-phase installations.

1" × 1" Connections: Compatible with common domestic and irrigation pipework.

Product Summary

The LEO 4ACm100S is a 1 HP / 0.75 kW, 220V single-phase, four-stage stainless-steel horizontal multistage centrifugal pump designed for clean-water transfer, domestic water supply, high-rise water supply, pressure boosting, irrigation and long-distance water transfer. LEO's official ACm-S series documentation specifically identifies these types of applications.

The Malaysian specification lists 5–90 L/min flow, 43.5–5 m head, 8 m maximum suction height and 1" × 1" inlet/outlet connections.



 Inquiry - LEO MULTISTAGE CENTRIFUGAL PUMPS - 4ACM-100S