LEO SEWAGE SUBMERSIBLE PUMPS - LSWM 200XA



The LEO LSWM 200XA is an automatic 2 HP / 1.5 kW sewage submersible pump designed for high-capacity wastewater, sewage and dirty-water drainage. It is particularly suitable for sewage collection pits, wastewater tanks, septic systems, factories, construction sites, commercial facilities, municipal sewage-treatment systems and agricultural drainage.

Published Malaysian product information identifies the LSWM200XA as a 2 HP / 1.5 kW, 220 V single-phase pump with a 2-inch discharge, automatic float-switch operation and a vortex impeller. One Malaysian listing specifies 447 L/min maximum flow and 17 m maximum head, while another local listing identifies the same model as equivalent to XSP32-17/1.5I and gives a higher 533 L/min maximum-flow figure. For a product catalogue, I recommend using the more directly model-specific 447 L/min / 17 m specification and treating the flow figure as subject to the applicable performance curve.

LEO's official SW series documentation describes its sewage submersible pumps as centrifugal pumps intended for wastewater drainage, sewage pumping, industrial pumping and similar applications, with IPX8 protection, Class F insulation, stainless-steel welded shafts and double mechanical seals.

Product Specifications

Specification Details
Brand LEO
Model LSWM 200XA
Pump Type Automatic Sewage Submersible Pump
Impeller Type Vortex Impeller
Motor Power 1.5 kW
Motor Rating 2 HP
Voltage 220 V
Frequency 50 Hz
Phase Single Phase
Maximum Flow 447 L/min*
Maximum Flow Approx. 26.8 m³/h*
Maximum Head 17 m
Discharge Outlet 2"
Solid Passage 30 mm*
Automatic Control Float Switch
Motor Winding Copper
Shaft AISI 304 Stainless Steel
Motor Protection Built-In Thermal Protector
Insulation Class F
Protection Class IPX8
Maximum Liquid Temperature 40°C
Maximum Immersion Depth 5 m
Pump Construction Stainless Steel / Cast Iron components
Installation Fully Submersible

*Specifications can vary between regional LEO listings. The Malaysian Hup Sheng listing gives 447 L/min, 17 m head and 30 mm solid passage, while another Malaysian listing gives 533 L/min. Verify the nameplate/performance curve for the exact stock unit before publishing a guaranteed flow figure.

2 HP / 1.5 kW Motor

The LSWM200XA is powered by a 1.5 kW / 2 HP motor, providing considerably higher capacity than the smaller LSWM75XA, LSWM100XA and LSWM150XA models.

The Malaysian specification is 220 V, 50 Hz, single phase, making the pump suitable for installations where single-phase electrical supply is available.

The motor uses copper windings and incorporates a built-in thermal protector. The LSWM series uses a sealed motor arrangement designed for submerged operation.

447 L/min Maximum Flow

The Malaysian LSWM200XA listing specifies a maximum flow of 447 L/min, equivalent to approximately 26.8 m³/h.

This makes the pump suitable for relatively high-volume wastewater transfer and drainage applications.

Typical applications include:

  • Sewage collection pits
  • Wastewater storage tanks
  • Septic tanks
  • Drainage sumps
  • Factory wastewater
  • Construction-site drainage
  • Commercial wastewater systems
  • Municipal sewage-treatment drainage
  • Agricultural drainage
  • Methane pools and field irrigation systems

The maximum flow figure should not be interpreted as the flow available at maximum head. Actual flow depends on the system's total dynamic head and the pump's Q-H performance curve.

17-Metre Maximum Head

The LSWM200XA is specified with a maximum head of 17 metres.

This gives the pump a useful operating range for applications involving moderate-to-high vertical lifting.

Suitable applications can include:

  • Deep sewage pits
  • Basement drainage
  • Wastewater collection tanks
  • Septic systems
  • Commercial drainage stations
  • Construction drainage
  • Long discharge runs with appropriate pipe sizing
  • Municipal wastewater systems

The 17 m figure represents maximum shut-off head, not the lifting height at which the pump will still produce its maximum flow.

The required system head should be calculated as:

Total Dynamic Head = Static Lift + Pipe Friction Loss + Fitting Losses + Valve/Check-Valve Losses

2-Inch Discharge Outlet

The LSWM200XA uses a 2-inch discharge connection.

A properly sized discharge pipe is essential for maintaining hydraulic performance. Using an undersized hose or excessive fittings can create substantial friction losses and reduce the actual flow rate.

For longer discharge distances, pipe sizing should be determined based on the required flow, available head and allowable friction loss.

Vortex Impeller

The LSWM200XA is identified by Malaysian product information as a vortex-impeller sewage pump.

The vortex design creates a pumping action in which the liquid and suspended solids are moved through the pump without requiring the solids to pass directly through the centre of a tightly enclosed impeller passage.

This configuration is useful for wastewater containing:

  • Suspended solids
  • Organic matter
  • Sewage
  • Fibrous impurities
  • Dirty water
  • General wastewater contaminants

A published specification for the Malaysian model lists a 30 mm solid passage.

This does not mean that any 30 mm object can safely be pumped regardless of shape. Long fibres, ropes, cloth, plastic bags and other flexible materials can still cause blockage.

Automatic Float-Switch Operation

The XA version is designed for automatic operation using a float switch.

The typical sequence is:

Wastewater level rises → Float activates → Pump starts → Water level falls → Float deactivates → Pump stops

This makes the pump particularly useful in:

  • Sewage pits
  • Sump pits
  • Drainage tanks
  • Wastewater collection tanks
  • Septic systems

The float must have sufficient freedom of movement and should not be allowed to become trapped against the pit wall, discharge pipe or other equipment.

AISI 304 Stainless-Steel Shaft

The LSWM200XA uses an AISI 304 stainless-steel fabricated shaft.

Stainless steel provides good corrosion resistance for a component continuously exposed to a wet wastewater environment.

The shaft is an important rotating component and must remain properly aligned with the bearings and mechanical seal for reliable operation.

Pump Construction

The Malaysian specification describes the LSWM200XA as incorporating a stainless-steel shell, cast-iron pump body with special anti-rust treatment and an AISI 304 shaft.

This combination provides a balance between structural strength, corrosion resistance and manufacturing durability.

The cast-iron pump body is treated for corrosion resistance, while stainless-steel components are used in areas requiring improved corrosion resistance.

Built-In Thermal Protection

The motor incorporates a built-in thermal protector.

This protection helps prevent excessive motor temperature during overload or abnormal operating conditions.

Thermal protection does not replace correct electrical installation. The pump should still be connected through appropriately rated electrical protection and installed according to applicable electrical standards.

Class F Insulation

The LSWM200XA is specified with Class F insulation.

Class F insulation provides suitable thermal resistance for the motor's electrical winding system.

LEO's general sewage-pump documentation also specifies Class F insulation for the range.

IPX8 Submersible Protection

The LSWM series is designed for submerged operation and uses IPX8 protection.

This makes it appropriate for installation inside sewage pits, wastewater tanks and drainage sumps.

Electrical connections, cable joints and grounding must nevertheless be properly installed. The pump should not be operated outside its specified immersion and environmental conditions.

5-Metre Maximum Immersion Depth

Published LSWM200XA specifications give a maximum immersion depth of 5 metres.

The pump should not be installed deeper than the manufacturer's specified maximum depth.

Correct positioning is also important to prevent the pump from drawing excessive settled sludge or debris from the bottom of the collection pit.

Operating Conditions

LEO's LSW sewage-pump documentation specifies the following general operating conditions:

  • Maximum liquid temperature: 40°C
  • Liquid pH: 4–10
  • Maximum liquid density: 1200 kg/m³
  • Solid impurity volume ratio: Maximum 2%
  • Protection class: IPX8
  • Frequency: According to nameplate
  • Application: Wastewater, rainwater and sewage containing solid particles

The pump should not be used for strongly corrosive or strongly abrasive liquids unless material compatibility has been confirmed.

Mechanical Seal

The LEO LSW series uses double-end mechanical seals as part of its submerged pump construction.

The mechanical seal helps prevent pumped liquid from entering the motor chamber through the shaft.

This is particularly important for sewage pumps because the motor is positioned close to the hydraulic section and the entire assembly operates submerged.

Suitable Applications

LEO identifies its sewage submersible pump range for wastewater drainage, sewage pumping, industrial pumping and sewage management.

The LSWM200XA is particularly suitable for:

Residential Applications

  • Septic tanks
  • Sewage pits
  • Residential drainage stations
  • Basement wastewater

Commercial Applications

  • Commercial buildings
  • Hotels
  • Restaurants
  • Schools
  • Public buildings
  • Wastewater collection tanks

Industrial Applications

  • Factory wastewater
  • Food-processing wastewater
  • Industrial drainage pits
  • Wastewater transfer
  • General industrial wastewater

Construction Applications

  • Construction-site drainage
  • Excavation drainage
  • Temporary wastewater removal
  • Accumulated-water pumping

Municipal Applications

  • Sewage-treatment plants
  • Municipal drainage stations
  • Wastewater collection systems

Agricultural Applications

  • Farm wastewater
  • Methane pools
  • Field irrigation
  • Agricultural drainage

LEO specifically identifies wastewater drainage from factories and commercial facilities, municipal sewage-treatment drainage, residential drainage stations, septic systems and agricultural applications within its sewage-pump range.

Typical Installation

A typical installation can be arranged as:

Sewage / wastewater collection pit → LEO LSWM200XA → 2" discharge pipe → drainage / treatment / collection point

For a permanent installation, a suitable check valve may be installed in the discharge line to reduce reverse flow when the pump stops.

The pump should be positioned on a stable base or installed with an appropriate coupling system where required.

LEO's SW series supports flexible installation using hoses, pipes or quick-coupling systems depending on the configuration.

Pump Performance Considerations

The 447 L/min maximum flow and 17 m maximum head should not be treated as simultaneous operating conditions.

Actual performance depends on:

  1. Required flow rate.
  2. Static lifting height.
  3. Discharge-pipe diameter.
  4. Total pipe length.
  5. Number of elbows and fittings.
  6. Check-valve losses.
  7. Wastewater characteristics.
  8. Required discharge pressure.

A long discharge line or undersized pipe can create significant friction losses.

For engineering selection, the required duty point should be matched against the applicable LEO Q-H performance curve.

Main Product Advantages

  1. 2 HP / 1.5 kW motor for high-capacity sewage drainage.
  2. 447 L/min maximum published flow.
  3. Approximately 26.8 m³/h maximum flow.
  4. 17 m maximum head.
  5. 2-inch discharge outlet.
  6. Vortex impeller designed for wastewater containing impurities.
  7. 30 mm published solid passage.
  8. Automatic float-switch operation.
  9. Built-in thermal protection.
  10. Copper motor winding.
  11. AISI 304 stainless-steel shaft.
  12. Class F insulation.
  13. IPX8 protection.
  14. 5 m maximum immersion depth.
  15. Suitable for residential, commercial, industrial, construction, municipal and agricultural wastewater applications.

Product Details Summary

The LEO LSWM200XA is an automatic 2 HP / 1.5 kW sewage submersible pump designed for high-volume wastewater and sewage drainage. Operating at 220 V / 50 Hz single phase, the Malaysian specification lists a maximum flow of 447 L/min (approximately 26.8 m³/h) and a maximum head of 17 metres, with a 2-inch discharge outlet and 30 mm solid passage. Its vortex impeller configuration is designed for wastewater containing suspended impurities, while the pump incorporates an automatic float switch, built-in thermal protection, copper motor winding, AISI 304 stainless-steel shaft, Class F insulation and IPX8 protection. With a maximum immersion depth of approximately 5 metres, it is suitable for sewage pits, septic tanks, wastewater tanks, factories, commercial buildings, construction sites, municipal sewage-treatment systems and agricultural drainage.

SEO Product Title

LEO LSWM200XA Sewage Submersible Pump 2HP 1.5kW – 447L/min, 17M Head

SEO Product Description

LEO LSWM200XA Sewage Submersible Pump is an automatic 2HP / 1.5kW wastewater and sewage pump designed for high-capacity drainage of dirty water, sewage and wastewater containing suspended impurities. Operating at 220V/50Hz single phase, it delivers a published maximum flow of 447L/min (approximately 26.8m³/h) with a maximum head of 17 metres and features a 2-inch discharge outlet. The pump uses a vortex impeller with a published 30mm solid passage and incorporates automatic float-switch operation, built-in thermal protection, copper motor winding, AISI 304 stainless-steel shaft, Class F insulation and IPX8 submersible protection. The LEO LSWM200XA is suitable for sewage pits, septic tanks, wastewater collection tanks, construction sites, factories, commercial facilities, municipal sewage-treatment systems and agricultural drainage applications.



 Inquiry - LEO SEWAGE SUBMERSIBLE PUMPS - LSWM 200XA